If the PM2.5 concentration level display is abnormal, the following suspected areas may be the cause.
| Symptom | Factor |
|---|---|
| PM2.5 concentration level is not correctly displayed (level does not change) | ·
Air conditioning control panel malfunction ·
Clogged clean air filter ·
Air conditioning particulate matter sensor (air conditioning duct sub-assembly) not correctly installed ·
Air conditioning particulate matter sensor (Air conditioning duct sub-assembly) malfunction |
Check for DTCs.
| Result | Proceed to |
|---|---|
| B140196, B14B287 or B14C987 is not output | A |
| B140196, B14B287 or B14C987 is output | B |
A
B
to B140196: Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Gasoline Model)>B140196202111,999999,_58,_111841,_0499788,RM100000001Z1A7,B140196
to B14B287: Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Gasoline Model)>B14B287202111,999999,_58,_111841,_0499788,RM100000001Z07F,B14B287
Choose the problem to be inspected.
| Result | Proceed to |
|---|---|
| The PM2.5 concentration level is not displayed | A |
| The PM2.5 concentration level display does not change from red or yellow | B |
| The PM2.5 concentration level display does not change from green | C |
A
B
C
Visually check the clean air filter.
The clean air filter is not dirty or clogged.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| PM Sensor Contamination Level | Air conditioning particulate matter sensor (Air conditioning duct sub-assembly) | 0 to 65535 | Actual PM concentration level is displayed | - |
| Tester Display |
|---|
| PM Sensor Contamination Level |
The value of the display changes frequently.
As the value range is large, it is expected that the value will continually fluctuate around a certain value even if the actual PM concentration level inside the vehicle does not change.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
Set the air inlet mode to recirculation mode.
Set the PM2.5 removal mode switch to ON.
The PM2.5 concentration level display changes to green after a certain period of time.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the installation condition of the air conditioning particulate matter sensor (air conditioning duct sub-assembly).
The air conditioning particulate matter sensor (air conditioning duct sub-assembly) is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| PM Sensor Contamination Level | Air conditioning particulate matter sensor (Air conditioning duct sub-assembly) | 0 to 65535 | Actual PM concentration level is displayed | - |
| Tester Display |
|---|
| PM Sensor Contamination Level |
The value of the display changes frequently.
As the value range is large, it is expected that the value will continually fluctuate around a certain value even if the actual PM concentration level inside the vehicle does not change.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
NEXT
Set the air inlet mode to recirculation mode.
Set the PM2.5 removal mode switch to ON.
The PM2.5 concentration level display changes to yellow or red after a certain period of time.
The PM2.5 concentration level display changes to green after a certain period of time.
| Proceed to |
|---|
| OK |
| NG |
OK
NG