The No. 1 blower damper servo sub-assembly sends pulse signals to inform the air conditioning amplifier assembly of the damper position.
The air conditioning amplifier assembly activates the motor (normal or reverse) based on these signals to move the No. 1 blower damper servo sub-assembly to the appropriate position to change the air inlet mode (fresh, recirculation/fresh, and recirculation).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| B143B7F | Air Inlet Damper Control Servo Motor Actuator Stuck Off | Diagnosis Condition:
No. 1 blower damper servo sub-assembly operating Malfunction: ·
Air inlet damper servo operation request signals are output but the air inlet damper position sensor value does not change. ·
Air inlet damper servo operation request signals are output but the air inlet damper position sensor value is abnormal. Detection Time: Continuously for 30 seconds or more |
·
No. 1 blower damper servo sub-assembly ·
No. 1 air conditioning radiator damper servo sub-assembly ·
Air conditioning harness assembly ·
Blower assembly |
Memorized | Air Conditioner | A |
| Vehicle Condition | |||
|---|---|---|---|
| Pattern 1 | Pattern 2 | ||
| Diagnosis Condition | No. 1 blower damper servo sub-assembly operating | ○ | ○ |
| Malfunction | Air inlet damper servo operation request signals are output but the air inlet damper position sensor value does not change. | ○ | - |
| Air inlet damper servo operation request signals are output but the air inlet damper position sensor value is abnormal. | - | ○ | |
| Detection Time | Continuously for 30 seconds or more | Continuously for 30 seconds or more | |
| Trip Count | 1 trip | 1 trip | |
If the conditions of either of these patterns are detected, a DTC will be stored.
This DTC is also output for the damper link, damper lock, etc. Before performing inspection, perform servomotor initialization and check that there are no mechanical malfunctions.
This DTC is also output when servomotor initialization has failed. When servomotor initialization has failed, repair any malfunctions and perform servomotor initialization again.
Check that the No. 1 blower damper servo sub-assembly is installed correctly.
No. 1 blower damper servo sub-assembly is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for a wire harness caught between the links of the motors and dampers.
No wire harnesses are caught between the links of the motors and dampers.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Inlet Damper Control Servo Motor | This test activates the air inlet damper control servo motor.
(No. 1 blower damper servo sub-assembly) |
128: Min
384: Max |
Operate with the ignition switch ON. |
| Tester Display | Measurement Item | Range | Normal Condition | Inspection Item |
|---|---|---|---|---|
| Air Inlet Damper Control Servo Motor Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse | 128 to 384 | ·
Fresh: 220 (pulse) ·
Recirculation: 256 (pulse) |
No. 1 blower damper servo sub-assembly circuit malfunction |
| Active Test Display |
|---|
| Air Inlet Damper Control Servo Motor |
| Data List Display |
|---|
| Air Inlet Damper Control Servo Motor Actual Pulse |
The value of the Data List changes in accordance with the operation of the Active Test.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Inlet Damper Control Servo Motor | This test activates the air inlet damper control servo motor.
(No. 1 blower damper servo sub-assembly) |
128: Min
384: Max |
Operate with the ignition switch ON. |
| Tester Display | Measurement Item | Range | Normal Condition | Inspection Item |
|---|---|---|---|---|
| Air Inlet Damper Control Servo Motor Target Pulse | No. 1 blower damper servo sub-assembly target pulse | 128 to 384 | ·
Fresh: 220 (pulse) ·
Recirculation: 256 (pulse) |
No. 1 blower damper servo sub-assembly circuit malfunction |
| Air Inlet Damper Control Servo Motor Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse | 128 to 384 | ·
Fresh: 220 (pulse) ·
Recirculation: 256 (pulse) |
No. 1 blower damper servo sub-assembly circuit malfunction |
| Active Test Display |
|---|
| Air Inlet Damper Control Servo Motor |
| Data List Display |
|---|
| Air Inlet Damper Control Servo Motor Target Pulse |
| Air Inlet Damper Control Servo Motor Actual Pulse |
The target pulse value of the Data List matches the actual pulse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Disconnect the A No. 1 air conditioning radiator damper servo sub-assembly connector.
Disconnect the B No. 1 blower damper servo sub-assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A-6 (STE2) - B-3 (sigB) | Always | Below 1 Ω |
| A-5 (STE1) - B-2 (sigA) | Always | Below 1 Ω |
| A-8 (M-) - B-5 (M-) | Always | Below 1 Ω |
| A-7 (M+) - B-4 (M+) | Always | Below 1 Ω |
| A-4 (GND) - B-1 (GND) | Always | Below 1 Ω |
| A-6 (STE2) or B-3 (sigB) - Other terminals and body ground | Always | 10 kΩ or higher |
| A-5 (STE1) or B-2 (sigA) - Other terminals and body ground | Always | 10 kΩ or higher |
| A-8 (M-) or B-5 (M-) - Other terminals and body ground | Always | 10 kΩ or higher |
| A-7 (M+) or B-4 (M+) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Inlet Damper Control Servo Motor | This test activates the air inlet damper control servo motor.
(No. 1 blower damper servo sub-assembly) |
128: Min
384: Max |
Operate with the ignition switch ON. |
| Tester Display | Measurement Item | Range | Normal Condition | Inspection Item |
|---|---|---|---|---|
| Air Inlet Damper Control Servo Motor Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse | 128 to 384 | ·
Fresh: 220 (pulse) ·
Recirculation: 256 (pulse) |
No. 1 blower damper servo sub-assembly circuit malfunction |
| Active Test Display |
|---|
| Air Inlet Damper Control Servo Motor |
| Data List Display |
|---|
| Air Inlet Damper Control Servo Motor Actual Pulse |
The value of the Data List changes in accordance with the operation of the Active Test.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Front Air Outlet Damper Control Servo Motor | This test activates the front air outlet damper control servo motor.
(No. 1 air conditioning radiator damper servo sub-assembly (front side mode)) |
128: Min
384: Max |
Operate with the ignition switch ON. |
| Tester Display | Measurement Item | Range | Normal Condition | Inspection Item |
|---|---|---|---|---|
| Front Air Outlet Damper Control Servo Motor Actual Pulse | No. 1 air conditioning radiator damper servo sub-assembly (front side mode) actual pulse | 128 to 384 | ·
S-FLOW: 234 (pulse) ·
FACE: 256 (pulse) ·
B/L: 267 (pulse) ·
FOOT-A: 288 (pulse) ·
FOOT-R (F): 297 (pulse) ·
FOOT-D: 305 (pulse) ·
F/D-R: 320 (pulse) ·
D/F: 339 (pulse) ·
DEF: 348 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (front side mode) circuit malfunction |
| Active Test Display |
|---|
| Front Air Outlet Damper Control Servo Motor |
| Data List Display |
|---|
| Front Air Outlet Damper Control Servo Motor Actual Pulse |
The value of the Data List changes in accordance with the operation of the Active Test.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Remove the No. 1 blower damper servo sub-assembly.
Procedure1
Operate the dampers by hand.
The dampers are easily operated by hand.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG