87130D
1.INSTALL BLOWER ASSEMBLY (for LHD)
Attach the claw and guide to install the blower assembly.
| *A | except Automatic Air Conditioning System | *B | for Automatic Air Conditioning System |
Install the 2 screws.
for Automatic Air Conditioning System:
Connect the connector to the No. 1 blower damper servo sub-assembly.
Attach the guide.
w/ PTC Heater:
| *A | for Automatic Air Conditioning System |
| *B | except Automatic Air Conditioning System |
Attach the guide and connect the blower assembly side of the No. 2 cooler wiring.
Install the screw.
87130D
2.INSTALL BLOWER ASSEMBLY (for RHD)
Attach the claw and guide to install the blower assembly.
| *A | except Automatic Air Conditioning System | *B | for Automatic Air Conditioning System |
Install the 2 screws.
for Automatic Air Conditioning System:
Connect the connector to the No. 1 blower damper servo sub-assembly.
Attach the guide.
w/ PTC Heater:
Attach the guide and connect the blower assembly side of the No. 2 cooler wiring.
Install the screw.
3.INSTALL AIR CONDITIONER UNIT ASSEMBLY
4.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
5. INITIALIZATION AFTER RECONNECTING BATTERY TERMINAL
When disconnecting and reconnecting the battery, there is an automatic learning function that completes learning when the respective system is used.
6. INITIALIZE SERVO MOTOR (for Automatic Air Conditioning System)
7.PERFORM DIAGNOSTIC SYSTEM CHECK
8.CHECK SRS WARNING LIGHT