RM35X0E _V1 General _081196 SETUP _0393338 WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL F

SETUP  WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL  AUTOMATIC LEARNING CHART  


AUTOMATIC LEARNING PERFORMED WHEN CABLE IS DISCONNECTED/RECONNECTED TO BATTERY TERMINAL


When the cable is disconnected/reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.

·

Learning completes when vehicle is driven

Effect/Inoperative Function When Necessary Procedures are not Performed Necessary Procedures Link

*: w/ Stop and start system

Stop and start system* Drive the vehicle until stop and start control is permitted (approximately 5 to 60 minutes). (Click here)
Lane control system Drive the vehicle straight ahead at 15 km/h (10 mph) or more for 1 second or more. (Click here)
Pre-collision system


·

Learning completes when vehicle is operated normally

Effect/Inoperative Function When Necessary Procedures are not Performed Necessary Procedures Link
Power slide door system Fully close the slide door by hand.
HINT:

Initialization is not necessary if the above procedures are performed while the slide door is closed.


(Click here)
Air conditioning system After the ignition switch is turned to ON, the servo motor standard position is recognized. -