This DTC is stored when the blind spot monitor sensor LH (B) detects a short to ground in the outer rear view mirror indicator LH.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from | Priority |
|---|---|---|---|---|---|
| C1AB411 | Outer Mirror Indicator (Module "B" Side) Circuit Short to Ground | Both of the following conditions are met:
·
The blind spot monitor system is on ·
The current that is sent from the blind spot monitor sensor to the indicator is above a specified level for a specified period of time |
·
Outer mirror LH (outer rear view mirror indicator LH) ·
Outer rear view mirror assembly LH ·
Harness or connector ·
Blind spot monitor sensor LH (B) |
Blind Spot Monitor "B" | A |
When checking for DTCs, make sure that the blind spot monitor system is turned on.
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
NEXT
Recheck for DTCs and check if the same DTC is output again.
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| DTCs are output | B |
A
B
Pre-procedure1
Disconnect the R1 blind spot monitor sensor LH (B) connector.
Disconnect the G15 outer rear view mirror assembly LH connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(R1)Location & Routingewd_type=routing;type=c;code=R1 Click Connector(R1)Body>Luggage Room Wire>Blind Spot Monitor Sensor LHewd_type=component;type=c;code=R1;pinno=4 |
||
| R1-4 (OMIL) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the B outer mirror LH (outer rear view mirror indicator LH) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G15)Location & Routingewd_type=routing;type=c;code=G15 Click Connector(G15)Body>Front Door Wire RH / Front Door Wire LH>Outer Rear View Mirror Assembly LHewd_type=component;type=c;code=G15;pinno=15 |
||
| G15-15 (BSL+) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
| Proceed to |
|---|
| OK |
| NG |
OK
NG