RM36D0EC _57 Power Source / Network _083089 M20D-FKS BATTERY / CHARGING _0402337 CHARGING SYSTEM L

M20D-FKS BATTERY / CHARGING  CHARGING SYSTEM  PRECAUTION  


INITIALIZATION


Make sure to perform the necessary procedures (adjustment, calibration, initialization, or registration) after parts related to the charging system have been removed/installed or replaced.

HINT:
·

When the cable is disconnected / reconnected to the battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.

-

Learning completes when vehicle is driven

Effect/Inoperative when not Performed Necessary Procedures Link
Stop and start system Drive the vehicle until stop and start control is permitted (approximately 5 to 60 minutes). (Click here)
Lane tracing assist system Drive the vehicle straight ahead at 15 km/h (10 mph) or more for 1 second or more. (Click here)
Pre-collision system

-

Learning completes when vehicle is operated normally

Effect/Inoperative when not Performed Necessary Procedures Link

*: w/ Power back door system

Power back door function* Fully close the back door by hand.
HINT:

Initialization is not necessary if the above procedures are performed while the back door is closed.


(Click here)
Power door lock control system If the back door is locked and therefore cannot be opened, it is necessary to unlock the back door using the door control switch, electrical key transmitter sub-assembly switch. (Click here)
Air conditioning system After the ignition switch is turned to ON, the servo motor standard position is recognized -


·

After charging the battery, perform the integrated current value initialization.

Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION




CHARGING SYSTEM PRECAUTION



NOTICE:
·

Check that the battery cables are connected to the correct terminals.

·

Disconnect the battery cables when the battery is given a quick charge.

·

Do not perform tests with a high voltage insulation resistance tester.

·

Never disconnect the battery cables while the engine is running.

·

Check that the charging cable nuts are tightened on terminal B of the generator assembly and on the No. 1 engine room relay block.