If the fresh/recirculation mode does not change or exhaust gas can be smelled even while set to recirculation mode, the following causes are possible.
| Malfunction Status | Factor |
|---|---|
·
Fresh/recirculation mode does not change. ·
Exhaust gas can be smelled even while set to recirculation mode. |
·
Blower servo motor malfunction ·
Blower damper and link operation (jamming) ·
Foreign object jammed in door ·
Air conditioning radiator assembly malfunction |
Check that the No. 1 blower damper servo sub-assembly is installed correctly.
No. 1 blower damper servo sub-assembly is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the No. 1 blower damper servo sub-assembly.
Inspect the No. 1 blower damper servo sub-assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the N84 No. 1 blower damper servo motor sub-assembly connector.
Disconnect the N41 air conditioning amplifier assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| N84-5 (IG+) - Body ground | Ignition switch ON | 11 to 14 V |
| N84-5 (IG+) - Body ground | Ignition switch off | Below 1 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| N84-1 (REC) - N41-20 (REC) | Always | Below 1 Ω |
| N84-2 (FRS) - N41-21 (FRS) | Always | Below 1 Ω |
| N84-1 (REC) or N41-20 (REC) - Body ground | Always | 10 kΩ or higher |
| N84-2 (FRS) or N41-21 (FRS) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG