RM35X0E _58 Vehicle Interior _079316 HEATING / AIR CONDITIONING _0384878 BLOWER UNIT G

HEATING / AIR CONDITIONING  BLOWER UNIT  INSPECTION  


PROCEDURE

Hide 87130K 1.INSPECT NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (except Automatic Air Conditioning System)

a.
E416503C01
0.99,2.615 0.365,2.615 true 2.031,0.552 2.49,0.552 true 0.927,0.552 1.385,0.552 true 1.833,0.594 1.833,0.958 true 2.552,2.531 2.865,2.729 0.313,0.198 10 false *b 0.906,0.896 1.219,1.094 0.313,0.198 10 false *c 0.844,0.115 1.156,0.313 0.313,0.198 10 false *a 0.219,2.531 0.531,2.729 0.313,0.198 10 false *d 0.917,2.802 1.229,3 0.313,0.198 10 false *e 2.531,0.479 2.99,0.677 0.458,0.198 10 false REC 0.677,0.469 1.135,0.667 0.458,0.198 10 false IG+ 1.729,0.979 2.188,1.177 0.458,0.198 10 false FRS
*a Component without harness connected
(No. 1 Blower Damper Servo Sub-assembly)
*b Fresh Side
*c Recirculation Side
*d 133°57' +/- 3°30' (133.95° +/- 3.5°)
*e 180°


Apply battery voltage to the No. 1 blower damper servo sub-assembly and check the operation of the motor.

OK:
Measurement Condition Specified Condition
Battery positive (+) → Terminal 5 (IG+)
Battery negative (-) → Terminal 1 (REC)
Turns to the "RECIRCULATION" side smoothly
Battery positive (+) → Terminal 5 (IG+)
Battery negative (-) → Terminal 2 (FRS)
Turns to the "FRESH" side smoothly


If the result is not as specified, replace the No. 1 blower damper servo sub-assembly.