87130K
1.INSPECT NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (except Automatic Air Conditioning System)
| *a | Component without harness connected
(No. 1 Blower Damper Servo Sub-assembly) |
| *b | Fresh Side |
| *c | Recirculation Side |
| *d | 133°57' +/- 3°30' (133.95° +/- 3.5°) |
| *e | 180° |
Apply battery voltage to the No. 1 blower damper servo sub-assembly and check the operation of the motor.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 5 (IG+)
Battery negative (-) → Terminal 1 (REC) |
Turns to the "RECIRCULATION" side smoothly |
| Battery positive (+) → Terminal 5 (IG+)
Battery negative (-) → Terminal 2 (FRS) |
Turns to the "FRESH" side smoothly |
If the result is not as specified, replace the No. 1 blower damper servo sub-assembly.