RM35X0E _51 Engine / Hybrid System _078884 CRUISE CONTROL _0383150 LANE CONTROL SYSTEM J

CRUISE CONTROL  LANE CONTROL SYSTEM  Steering Pad Switch Circuit  


DESCRIPTION

The forward recognition camera receives LDA main switch signals from the steering pad switch assembly.

WIRING DIAGRAM

A406735E32
1.5,1.281 2.74,1.698 1.24,0.417 10 false LDA Main Switch 1.042,2.281 3.188,2.542 2.146,0.26 10 false Steering Pad Switch Assembly 3.052,1.625 4.146,2.031 1.094,0.406 10 false Spiral Cable Sub-assembly 5.031,0.979 7.021,1.167 1.99,0.188 10 false Forward Recognition Camera 4.063,0.49 4.521,0.688 0.458,0.198 10 false G4 4.063,1.104 4.521,1.302 0.458,0.198 10 false G4 2.906,0.5 3.365,0.698 0.458,0.198 10 false z2 2.906,1.115 3.365,1.313 0.458,0.198 10 false z2 3.427,0.406 4.042,0.604 0.615,0.198 10 false DIST 3.417,1.01 4.031,1.208 0.615,0.198 10 false ECC 5.042,0.833 5.427,1.052 0.385,0.219 9 false Q12 5.375,0.521 5.875,0.719 0.5,0.198 10 false LKSW 5.198,0.406 5.51,0.604 0.313,0.198 10 false 3 4.083,0.302 4.396,0.5 0.313,0.198 10 false 12 4.125,0.906 4.438,1.104 0.313,0.198 10 false 2 2.948,0.906 3.26,1.104 0.313,0.198 10 false 7 2.938,0.302 3.25,0.5 0.313,0.198 10 false 4 2.438,0.385 3.052,0.583 0.615,0.198 10 false DIST 2.448,1 2.906,1.198 0.458,0.198 10 false ECC

CAUTION / NOTICE / HINT

NOTICE:

The vehicle is equipped with a Supplemental Restraint System (SRS) which includes components such as airbags. Before servicing (including removal or installation of parts), be sure to read the precaution for Supplemental Restraint System.

for Type A: Click hereVehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>AIRBAG SYSTEM (for Type A)>PRECAUTION

for Type B: Click hereVehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>AIRBAG SYSTEM (for Type B)>PRECAUTION


PROCEDURE

3.CHECK HARNESS AND CONNECTOR (SPIRAL CABLE SUB-ASSEMBLY - FORWARD RECOGNITION CAMERA)
a.

Disconnect the N58 spiral cable sub-assembly connector.


b.

Disconnect the a9 forward recognition camera connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
N58-6 (DIST) - a9-3 (LKSW) Always Below 1 Ω
N58-6 (DIST) or a9-3 (LKSW) - Body ground Always 10 kΩ or higher



d.

Connect the a9 forward recognition camera connector.


e.

Connect the N58 spiral cable sub-assembly connector.


Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR