| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | Memory |
|---|---|---|---|---|---|
| C05D81C | 4WD/AWD Clutch "A" Actuator Control Circuit Performance Circuit Voltage Out of Range | ·
The command current of the front 4WD linear solenoid is 0 A and the short circuit continues for 1 second or more ·
The command current of the front 4WD linear solenoid is 3.0 A or higher and the open circuit continues for 0.5 seconds or more |
·
Wire harness or connector ·
Front 4WD linear solenoid (transfer assembly) ·
4WD ECU assembly |
Displayed | Yes |
| Vehicle Condition | |||
|---|---|---|---|
| Pattern 1 | Pattern 2 | ||
| Diagnosis Condition | The command current of the front 4WD linear solenoid is 0 A | ○ | - |
| The command current of the front 4WD linear solenoid is 3.0 A | - | ○ | |
| Malfunction Status | Short circuit | ○ | - |
| Open circuit | - | ○ | |
| Detection Time | 1 second or more | 0.5 seconds or more | |
| Number of Trips | 1 trip | 1 trip | |
DTC will be output when conditions for either of the patterns in the table above are met.
When the 4WD ECU assembly is replaced, before removing the 4WD ECU assembly, it is necessary to perform ECU Data Save to save the original 4WD ECU assembly information.
After performing repairs, clear the DTCs and check that the DTCs are not output again.
Turn the engine switch off.
Disconnect the N3 4WD ECU assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| N3-5 (SLF+) - N3-6 (SLF-) | 20°C (68°F) | 0.73 to 0.83 Ω |
| N3-5(SLF+) - Body ground | Always | 10 kΩ or higher |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| N3-6(SLF-) - Body ground | Always | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the engine switch off.
Disconnect the C60 front 4WD linear solenoid (transfer assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| N3-5(SLF+) - C60-2(SLF+) | Always | Below 1 Ω |
| N3-6(SLF-) - C60-1(SLF-) | Always | Below 1 Ω |
| N3-5(SLF+) or C60-2(SLF+) - Body ground | Always | 10 kΩ or higher |
| N3-6(SLF-) or C60-1(SLF-) - Body ground | Always | 10 kΩ or higher |
| N3-5(SLF+) or C60-2(SLF+) - N3-6(SLF-) or C60-1(SLF-) | Always | 10 kΩ or higher |
| N3-5(SLF+) - N3-16(SLFS) | Always | 10 kΩ or higher |
| N3-6(SLF-) - N3-16(SLFS) | Always | 10 kΩ or higher |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| N3-6(SLF-) or C60-1(SLF-) - Body ground | Always | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG