RM38N0EC _57 Power Source / Network _111789 M20C-FKS, M20D-FKS BATTERY / CHARGING _0506213 CHARGING SYSTEM C

M20C-FKS, M20D-FKS BATTERY / CHARGING  CHARGING SYSTEM  P065C07  Generator "A" Mechanical Performance Mechanical Failure  


DESCRIPTION

The alternator performs self-diagnosis of its internal circuits to detect malfunctions (open or short circuits).

The ECM receives the result via LIN communication and stores a DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate Note
P065C07 Generator "A" Mechanical Performance Mechanical Failure Alternator speed is less than 560 rpm, and EXC circuit is ON.
(1 trip detection logic)
·

Fan and generator V belt

·

V-Ribbed belt tensioner assembly

·

Generator assembly wiring

·

Generator assembly


Charge warning is displayed SAE Code: P065C

HINT:

A charge warning is displayed only when the malfunction continues.


CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following procedure.


PROCEDURE

3.CHECK GENERATOR ASSEMBLY WIRING

OK

4.CHECK FOR ABNORMAL NOISE

NG

REPAIR OR REPLACE GENERATOR ASSEMBLY WIRING