RM38N0EC _57 Power Source / Network _111789 M20C-FKS, M20D-FKS BATTERY / CHARGING _0506213 CHARGING SYSTEM C

M20C-FKS, M20D-FKS BATTERY / CHARGING  CHARGING SYSTEM  P062049  Generator Control Circuit Internal Electronic Failure  


DESCRIPTION

The alternator performs self-diagnosis of its internal circuits to detect malfunctions (open or short circuits).

The ECM receives the result via LIN communication and stores a DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate Note
P062049 Generator Control Circuit Internal Electronic Failure Open or short in EXC circuit, or abnormal waveform for PH circuit.
(1 trip detection logic)
Generator assembly Charge warning is displayed SAE Code: P0620

HINT:

A charge warning is displayed only when the malfunction continues.


WIRING DIAGRAM

A509795E02
3.135,1.688 3.594,1.885 0.458,0.198 10 false A101 3.146,1.833 4.344,2.219 1.198,0.385 10 false Battery State Sensor Assembly 6.125,3.229 6.583,3.427 0.458,0.198 10 false ECM 4.24,4.792 5.135,5.021 0.896,0.229 10 false IC Regulator 4.01,5.771 5.438,5.99 1.427,0.219 10 false Generator Assembly 1.344,0.896 2.302,1.094 0.958,0.198 10 false BATT-S NO. 2 2.365,2.99 2.76,3.177 0.396,0.188 10 false ALT 3.188,1.417 3.5,1.615 0.313,0.198 10 false +B 3.198,0.729 3.813,0.927 0.615,0.198 10 false RBAT 3.875,1.042 4.333,1.24 0.458,0.198 10 false LIN 5.823,1.063 6.281,1.26 0.458,0.198 10 false LIN 5.833,2.229 6.146,2.427 0.313,0.198 10 false E1 4.729,3.75 5.188,3.948 0.458,0.198 10 false LIN 4.51,4.021 4.969,4.219 0.458,0.198 10 false LIN 3.469,3.74 3.625,3.938 0.156,0.198 10 false B 3.854,4.01 4.01,4.208 0.156,0.198 10 false B 3.854,4.604 4.115,4.802 0.26,0.198 10 false P 3.854,5.188 4.271,5.365 0.417,0.177 10 false F 3.844,5.406 4.25,5.583 0.406,0.177 10 false E 3.292,3.479 3.906,3.677 0.615,0.198 10 false C39 4.49,3.479 4.948,3.677 0.458,0.198 10 false C83 3.667,3.49 3.823,3.688 0.156,0.198 10 false 1 4.844,3.5 5,3.698 0.156,0.198 10 false 2 3,0.615 3.156,0.813 0.156,0.198 10 false 1 3.01,1.313 3.167,1.51 0.156,0.198 10 false 3 4.208,0.865 4.365,1.063 0.156,0.198 10 false 2 5.427,1.052 6.042,1.25 0.615,0.198 10 false C115 5.417,2.219 6.031,2.417 0.615,0.198 10 false A109 5.5,0.813 5.813,1.01 0.313,0.198 10 false 90 5.49,1.99 5.802,2.188 0.313,0.198 10 false 22 0.719,4.49 1.302,4.917 0.583,0.427 10 false Battery 0.698,6.427 2.375,6.625 1.677,0.198 10 false : LIN Communication Line 1.323,1.635 2.281,1.833 0.958,0.198 10 false BATT-S NO. 1 0.531,3.25 1.604,3.448 1.073,0.198 10 false FL MAIN

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.