RM38N0EC _57 Power Source / Network _111829 NETWORKING _0505700 CXPI COMMUNICATION SYSTEM U

NETWORKING  CXPI COMMUNICATION SYSTEM  TERMINALS OF ECU  


NOTICE:
·

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

When disconnecting the cable from the negative (-) auxiliary battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE



CHECK POWER DISTRIBUTION BOX ASSEMBLY AND MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)


B704094N01
3.396,3.25 3.781,3.479 0.385,0.229 1.521,4.5 1.906,4.729 0.385,0.229 3.875,4.5 4.26,4.729 0.385,0.229 5.698,4.5 6.083,4.729 0.385,0.229 1.146,6.104 1.531,6.333 0.385,0.229 2.938,6.104 3.323,6.333 0.385,0.229 4.25,6.104 4.635,6.333 0.385,0.229 3.438,7.781 3.823,8.01 0.385,0.229 1.24,3.24 1.625,3.469 0.385,0.229 5.26,6.104 5.646,6.333 0.385,0.229 6.26,6.104 6.646,6.333 0.385,0.229 5.458,3.25 5.844,3.479 0.385,0.229 1.958,1.229 2.26,1.229 false 4.26,0.813 4.26,0.26 4.26,0.26 4.438,0.26 false 1.958,1.552 2.26,1.552 false 1.958,1.875 2.26,1.875 false 0.969,1.885 1.281,2.083 0.313,0.198 10 false 4H 1.167,2.385 1.479,2.583 0.313,0.198 10 false 4F 0.979,1.083 1.292,1.281 0.313,0.198 10 false 4E 0.979,1.594 1.292,1.792 0.313,0.198 10 false 4D 6.052,2.094 6.365,2.292 0.313,0.198 10 false 4A 2.333,1.49 2.792,1.688 0.458,0.198 10 false E36 2.333,1.813 2.792,2.01 0.458,0.198 10 false E37 4.5,0.198 4.885,0.385 0.385,0.188 10 false MB 1.333,3.292 1.802,3.5 0.469,0.208 10 false E37 3.49,3.292 3.948,3.49 0.458,0.198 10 false E36 3.052,6.146 3.51,6.344 0.458,0.198 10 false 4D 5.813,4.542 6.271,4.74 0.458,0.198 10 false 4A 3.542,7.813 4,8.01 0.458,0.198 10 false MB 6.031,1.729 6.344,1.927 0.313,0.198 10 false 4B 6.031,1.146 6.344,1.344 0.313,0.198 10 false 4C 0.969,2.146 1.281,2.344 0.313,0.198 10 false 4G 3.979,4.552 4.292,4.75 0.313,0.198 10 false 4B 1.635,4.542 1.948,4.74 0.313,0.198 10 false 4C 1.26,6.135 1.573,6.333 0.313,0.198 10 false 4E 4.365,6.146 4.677,6.344 0.313,0.198 10 false 4H 5.354,6.146 5.667,6.344 0.313,0.198 10 false 4G 6.375,6.146 6.688,6.344 0.313,0.198 10 false 4F 5.542,3.302 6,3.5 0.458,0.198 10 false E38 2.323,1.156 2.781,1.354 0.458,0.198 10 false E38


b.

Reconnect the power distribution box assembly connectors.


c.

Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol) Terminal Description Condition Specified Condition
MB-13 (GND1) - Body ground Ground Always Below 1 Ω
MB-14 (GND2) - Body ground Ground Always Below 1 Ω
MB-26 (BECU) - Body ground Auxiliary battery power supply Always*1
Ignition switch off*2
11 to 14 V
MB-27 (IGR) - Body ground IG power supply Ignition switch off Below 1 V
Ignition switch ON 11 to 14 V

*1: for Gasoline Model

*2: for HV Model




e.

Measure the voltage and check for pulses according to the value(s) in the table below.

Terminal No. (Symbol) Terminal Description Condition Specified Condition
4D-5 - Body ground CXPI communication line Ignition switch ON Pulse generation