The ambient temp. sensor (thermistor assembly) is installed in front of the cooler condenser assembly to detect the ambient temperature, which is used to control the air conditioning system. This sensor is connected to the air conditioning amplifier assembly and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the ambient temp. sensor (thermistor assembly) changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage to the ambient temp. sensor (thermistor assembly) and reads voltage changes due to changes in the resistance of the ambient temp. sensor (thermistor assembly).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P007015 | Ambient Temperature Sensor Circuit Short to Battery or Open | Diagnosis Condition:
Ignition switch ON Malfunction: Open or short (+B) in ambient temperature sensor circuit Detection Time: Continuously for 4 seconds or more |
·
Ambient temp. sensor (Thermistor assembly) ·
Harness or connector ·
Air conditioning amplifier assembly |
Memorized | Air Conditioner | A |
| Vehicle Condition | |||
|---|---|---|---|
| Pattern 1 | Pattern 2 | ||
| Diagnosis Condition | Ignition switch ON | ○ | ○ |
| Malfunction | Open in ambient temperature sensor circuit | ○ | - |
| Short (+B) in ambient temperature sensor circuit | - | ○ | |
| Detection Time | Continuously for 4 seconds or more | Continuously for 4 seconds or more | |
| Trip Count | 1 trip | 1 trip | |
If the conditions of either of these patterns are detected, a DTC will be stored.
Pre-procedure1
| *a | Front view of wire harness connector
(to Ambient Temp. Sensor (Thermistor Assembly)) |
Disconnect the A20 ambient temp. sensor (thermistor assembly) connector.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A20)Location & Routingewd_type=routing;type=c;code=A20 Click Connector(A20)Engine Compartment>Engine Room Main Wire / Transmission Wire>Thermistor Assemblyewd_type=component;type=c;code=A20;pinno=2 |
||
| A20-2 - Body ground | Ignition switch ON | 0 to 5.5 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
Turn the ignition switch off.
| *a | Front view of wire harness connector
(to Ambient Temp. Sensor (Thermistor Assembly)) |
Disconnect the A20 ambient temp. sensor (thermistor assembly) connector.
| *1 | Ambient Temp. Sensor (Thermistor Assembly) |
| *2 | Air Conditioning Amplifier Assembly |
Connect terminals 1 and 2 of the ambient temp. sensor (thermistor assembly) connector on the wire harness side.
Turn the ignition switch to ON and wait for 4 seconds or more.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P007011 is output | A |
| P007015 is output | B |
Post-procedure1
None
A
B
Pre-procedure1
Disconnect the A20 ambient temp. sensor (thermistor assembly) connector.
Disconnect the E45 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A20,E45)Location & Routingewd_type=routing;type=c,c;code=A20,E45 Click Connector(A20)Engine Compartment>Engine Room Main Wire / Transmission Wire>Thermistor Assemblyewd_type=component;type=c;code=A20;pinno=2,1 Click Connector(E45)Instrument Panel>Instrument Panel Wire / Telephone Computer Wire>Air Conditioning Amplifier Assemblyewd_type=component;type=c;code=E45;pinno=1,14 |
||
| A20-2 - E45-1 (TAM) | Always | Below 1 Ω |
| A20-1 - E45-14 (SG-2) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the A20 ambient temp. sensor (thermistor assembly) connector.
Disconnect the E45 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A20,E45)Location & Routingewd_type=routing;type=c,c;code=A20,E45 Click Connector(A20)Engine Compartment>Engine Room Main Wire / Transmission Wire>Thermistor Assemblyewd_type=component;type=c;code=A20;pinno=2 Click Connector(E45)Instrument Panel>Instrument Panel Wire / Telephone Computer Wire>Air Conditioning Amplifier Assemblyewd_type=component;type=c;code=E45;pinno=1 |
||
| A20-2 or E45-1 (TAM) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG