The room temp. sensor (cooler thermistor) is installed in the instrument panel to detect the cabin temperature, which is used to control the air conditioning system. The resistance of the room temp. sensor (cooler thermistor) changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage to the room temp. sensor (cooler thermistor) and reads voltage changes due to changes in the resistance of the room temp. sensor (cooler thermistor).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| B141A11 | Room Temperature Sensor Circuit Short to Ground | Diagnosis Condition:
Ignition switch ON Malfunction: Short (GND) in room temperature sensor circuit Detection Time: Continuously for 4 seconds or more |
·
Room temp. sensor (cooler thermistor) ·
Harness or connector ·
Air conditioning amplifier assembly |
Memorized | Air Conditioner | A |
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
Turn the ignition switch off.
| *1 | Room Temp. Sensor (Cooler Thermistor) |
| *2 | Air Conditioning Amplifier Assembly |
Disconnect the room temp. sensor (cooler thermistor) connector.
Turn the ignition switch to ON and wait for 4 seconds or more.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| B141A11 is not output | A |
| B141A11 is output | B |
Post-procedure1
None
A
B
Pre-procedure1
Disconnect the E57 room temp. sensor (cooler thermistor) connector.
Disconnect the E45 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(E57,E45)Location & Routingewd_type=routing;type=c,c;code=E57,E45 Click Connector(E57)Instrument Panel>Instrument Panel Wire / Radio Wiring Sub-Assy / Telephone Computer Wire>Cooler Thermistor (Room Temperature Sensor)ewd_type=component;type=c;code=E57;pinno=1,2 Click Connector(E45)Instrument Panel>Instrument Panel Wire / Radio Wiring Sub-Assy / Telephone Computer Wire>Air Conditioning Amplifier Assemblyewd_type=component;type=c;code=E45;pinno=5,3 |
||
| E57-1 or E45-5 (TR) - Other terminals and body ground | Always | 10 kΩ or higher |
| E57-2 or E45-3 (SG-1) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG