RM36D0EC _57 Power Source / Network _083089 M20D-FKS BATTERY / CHARGING _0402340 BATTERY A

M20D-FKS BATTERY / CHARGING  BATTERY  REMOVAL  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the battery removal/installation are shown below.

HINT:

When the cable is disconnected / reconnected to the battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.

·

Learning completes when vehicle is driven

Effect/Inoperative when not Performed Necessary Procedures Link
Stop and start system Drive the vehicle until stop and start control is permitted (approximately 5 to 60 minutes). (Click here)
Lane tracing assist system Drive the vehicle straight ahead at 15 km/h (10 mph) or more for 1 second or more. (Click here)
Pre-collision system

·

Learning completes when vehicle is operated normally

Effect/Inoperative when not Performed Necessary Procedures Link

*: w/ Power back door system

Power back door function* Fully close the back door by hand.
HINT:

Initialization is not necessary if the above procedures are performed while the back door is closed.


(Click here)
Power door lock control system If the back door is locked and therefore cannot be opened, it is necessary to unlock the back door using the door control switch, electrical key transmitter sub-assembly switch. (Click here)
Air conditioning system After the ignition switch is turned to ON, the servo motor standard position is recognized -



PROCEDURE

Hide 1. PRECAUTION

NOTICE:
·

After turning the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When replacing the auxiliary battery, use a new auxiliary battery of the same dimensions and same capacity or more from the same class at a 20-hour rate.