RM36D0EC _56 Audio / Visual / Telematics _083087 TELEMATICS _0402655 TELEMATICS SYSTEM U

TELEMATICS  TELEMATICS SYSTEM  TERMINALS OF ECU  


TELEMATICS TRANSCEIVER


E503077N02
0.406,0.25 0.823,0.5 0.417,0.25 0.896,0.25 1.313,0.5 0.417,0.25 1.385,0.25 1.802,0.5 0.417,0.25 3.083,0.25 3.5,0.5 0.417,0.25 5.167,0.25 5.583,0.5 0.417,0.25 2.229,0.25 2.74,0.5 0.51,0.25 0.448,0.292 0.844,0.521 0.396,0.229 10 false ANT3 0.938,0.292 1.344,0.479 0.406,0.188 10 false ANT2 1.438,0.292 1.833,0.469 0.396,0.177 10 false ANT1 3.125,0.302 3.521,0.542 0.396,0.24 10 false G132 5.219,0.292 5.646,0.49 0.427,0.198 10 false G131 2.292,0.292 2.688,0.531 0.396,0.24 10 false G143

Terminal No. (Symbol) Terminal Description Condition Specified Condition
G131-1 (+B) - G131-20 (E) Power source (+B) Ignition switch off 11 to 14 V
G131-3 (SIG-) - G131-20 (E) Ground Always Below 1 V
G131-4 (IND1) - G131-20 (E) Emergency call switch red indicator illumination signal For 5 seconds after turning the ignition switch to ON 1 to 8.5 V
Ignition switch off Below 1 V
G131-5 (MCVD) - G131-20 (E) Telephone microphone assembly power supply Ignition switch ON 7.5 to 8.5 V
Ignition switch off Below 1 V
G131-6 (MCI+) - G131-20 (E) Microphone voice signal Voice being input to telephone microphone assembly A waveform synchronized with microphone voice signal is input
G131-7 (MCI-) - G131-20 (E) Microphone voice signal Always Below 1 V
G131-13 (GSW) - G131-20 (E) Collision detection signal Ignition switch ON Pulse generation
(Refer to waveform 1)
G131-14 (MUTE) - G131-20 (E) MUTE Signal Audio system playing Above 3.5 V
Emergency call mode Below 1 V
G131-15 (USBV) - G131-20 (E) USB power supply Ignition switch ON 4.75 to 5.25 V
Ignition switch off Below 1 V
G131-16 (MCO+) - G131-20 (E) Microphone voice signal Voice being input to telephone microphone assembly A waveform synchronized with microphone voice signal is input
G131-17 (VOT+) - G131-20 (E) Sent voice signal Calling while using the operator service A waveform synchronized with the received voice is output
G131-19 (IG2) - G131-20 (E) Power source (IG) Ignition switch ON 11 to 14 V
Ignition switch off Below 1 V
G131-20 (E) - Body ground Ground Always Below 1 Ω
G131-21 (SIG1) - G131-3 (SIG-) Emergency call switch button condition signal Emergency call switch not pressed 1.3 to 1.9 V
Emergency call switch pressed 0.5 to 0.8 V
G131-22 (IND2) - G131-20 (E) Emergency call switch green indicator illumination signal For 5 seconds after turning the ignition switch to ON 1 to 8.5 V
Ignition switch off Below 1 V
G131-23 (SGND) - G131-20 (E) Shield ground Always Below 1 Ω
G131-25 (CANP) CAN communication signal - -
G131-26 (CANN) CAN communication signal - -
G131-31 (USBG) - Body ground Shield ground Always Below 1 Ω
G131-32 (MCO-) - G131-20 (E) Microphone voice signal Always Below 1 V
G131-33 (VOT-) - G131-20 (E) Sent voice signal Calling while using the operator service A waveform synchronized with the received voice is output
G132-1 (SPI+) - G131-20 (E) Sound signal Audio system playing A waveform synchronized with sound signals is output
G132-2 (SPI-) - G131-20 (E) Sound signal Audio system playing A waveform synchronized with sound signals is output
G132-3 (SPO+) - G131-20 (E) Sound signal Audio system playing, or emergency call mode A waveform synchronized with sound signals is output
G132-4 (SPO-) - G131-20 (E) Sound signal Audio system playing, or emergency call mode A waveform synchronized with sound signals is output
G143-1 (USB-) USB communication line - -
G143-2 (USB+) USB communication line - -
G143-3 (USBS) - Body ground USB communication line Always Below 1 Ω

a.
E165239E22
0.1,2.23 0.491,2.461 0.391,0.230 10 GND

Reference (Oscilloscope waveform):

i.

Waveform 1

Item Condition
Tester Connection G131-13 (GSW) - G131-20 (E)
Tool Setting 5.0 V/DIV., 20 ms./DIV.
Vehicle Condition Ignition switch ON