If the airflow from the front registers is weak regardless of the blower speed setting displayed on the air conditioning control assembly, the following factors may be the cause.
| Symptom | Factor |
|---|---|
·
Airflow volume is constantly low ·
Airflow volume sometimes becomes low |
·
Blower motor with fan sub-assembly malfunction ·
Clogged clean air filter ·
Clogged No. 1 cooler evaporator sub-assembly or heater radiator unit sub-assembly fins ·
No. 1 cooler thermistor malfunction |
Operate the blower switch with the following conditions met and check that the airflow volume changes.
| Blower Speed | Condition |
|---|---|
| LO → HI | ·
Temperature setting: MAX COLD ·
Air outlet mode: FACE ·
A/C switch: Off |
Airflow volume increases.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Visually check the clean air filter.
The clean air filter is not dirty or clogged.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the installation condition of the No. 1 cooler thermistor.
The No. 1 cooler thermistor is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG