RM3660EC _58 Vehicle Interior _080733 HEATING / AIR CONDITIONING _0591215 AIR CONDITIONING SYSTEM(for Gasoline Model (NR Series) with Manual Air Conditioning System for Electrical Control Type) J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model (NR Series) with Manual Air Conditioning System for Electrical Control Type)  Weak Blower Output  


DESCRIPTION

If the airflow from the front registers is weak regardless of the blower speed setting displayed on the air conditioning control assembly, the following factors may be the cause.

Symptom Factor
·

Airflow volume is constantly low

·

Airflow volume sometimes becomes low


·

Blower motor with fan sub-assembly malfunction

·

Clogged clean air filter

·

Clogged No. 1 cooler evaporator sub-assembly or heater radiator unit sub-assembly fins

·

No. 1 cooler thermistor malfunction



PROCEDURE

1.CHECK AIR CONDITIONING SYSTEM
a.

Operate the blower switch with the following conditions met and check that the airflow volume changes.

Blower Speed Condition
LO → HI
·

Temperature setting: MAX COLD

·

Air outlet mode: FACE

·

A/C switch: Off



OK:

Airflow volume increases.



Result:
Proceed to
OK
NG



OK

2.CHECK CLEAN AIR FILTER

NG

2.CHECK CLEAN AIR FILTER
a.

Visually check the clean air filter.

Click hereGeneral>MAINTENANCE>AIR CONDITIONING FILTER>REMOVAL

OK:

The clean air filter is not dirty or clogged.



Result:
Proceed to
OK
NG



OK

3.CHECK NO. 1 COOLER THERMISTOR

NG

3.CHECK NO. 1 COOLER THERMISTOR
a.

Check the installation condition of the No. 1 cooler thermistor.

OK:

The No. 1 cooler thermistor is installed correctly.



Result:
Proceed to
OK
NG



OK

NG