RM3660EC _57 Power Source / Network _080760 NR Series BATTERY / CHARGING _0394911 CHARGING SYSTEM J

NR Series BATTERY / CHARGING  CHARGING SYSTEM  Charging Failure  


PROCEDURE

1.CHECK GENERATOR PULLEY WITH CLUTCH (ON-VEHICLE INSPECTION)
a.

Start the engine and visually check that the generator rotor assembly (fan) in the generator assembly is operating.

OK:

The generator rotor assembly (fan) is operating.



Result:
Proceed to
OK
NG



OK

2.CHECK GENERATOR PULLEY WITH CLUTCH (UNIT INSPECTION)

NG

2.CHECK GENERATOR PULLEY WITH CLUTCH (UNIT INSPECTION)

b.

Check the installation condition of the generator pulley cap.

OK:

The generator pulley cap is not loose or missing.



c.

Check for forming of particles due to friction (for dry type pulley) or grease leaks (for wet type pulley).

OK:

There are no large amounts of particles (for dry type pulley) or grease leaks (for wet type pulley).



d.

Check the generator pulley with clutch for misalignment (interference with the generator assembly).

OK:

The generator pulley with clutch is not misaligned (no interference with the generator assembly).



e.
A288972

Turn the generator pulley with clutch clockwise and counterclockwise by hand and check for noise.

OK:

Noise does not occur when turned in either direction.



f.

Turn the generator pulley with clutch clockwise and counterclockwise by hand and visually check for runout.

OK:

The generator pulley with clutch does not have runout.




Result:
Proceed to
OK
NG



OK

NG