If fresh/recirculation mode changes unintentionally and without permission, the following causes are possible.
| Malfunction Status | Factor |
|---|---|
·
Air inlet mode changes between recirculation/fresh randomly ·
Recirculation/fresh switch indicator is blinking |
·
Customize setting (for Automatic Air Conditioning System) ·
Change in ambient air temperature ·
Decrease in refrigerant pressure ·
Pressure sensor circuit malfunction ·
Engine coolant temperature (high) |
Use the following customize setting methods to check if the automatically fresh/recirculation mode is "ON". If the setting is on, select the setting to "OFF".
Check setting using GTS
Check setting by multi-display
Customize setting is "OFF".
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ambient Temperature Sensor | Ambient temperature | -327.68°C (-557.82°F) to 327.67°C (621.81°F) | Ambient temperature of thermistor assembly | - |
| Tester Display |
|---|
| Ambient Temperature Sensor |
The value of the display does not change frequently.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F)
Max.: 215°C (419°F) |
75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature.
|
| Tester Display |
|---|
| Coolant Temperature |
The value of the display does not change frequently.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Refrigerant gas pressure on high pressure side | -32.768 MPaG to 32.767 MPaG | Actual refrigerant pressure displayed | ·
Refrigerant line (gas leak etc.) ·
Air conditioning pressure sensor circuit |
| Tester Display |
|---|
| Regulator Pressure Sensor |
Install a manifold gauge set.
Read the manifold gauge pressure when the following conditions are met.
Prepare the vehicle according to the table below.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
Compare the values displayed in the Data List and on the manifold gauge.
The values displayed in the Data List and on the manifold gauge match.
| Proceed to |
|---|
| OK |
| NG |
OK
NG