RM38N0EC _58 Vehicle Interior _111835 METER / GAUGE / DISPLAY _0504958 METER / GAUGE SYSTEM(for TFT Meter Type) J

METER / GAUGE / DISPLAY  METER / GAUGE SYSTEM(for TFT Meter Type)  Hybrid System Indicator Malfunction  


DESCRIPTION

A hybrid system indicator has been included on this vehicle. In this circuit, the combination meter assembly receives the hybrid system indicator signal from the hybrid vehicle control ECU via CAN communication. The combination meter assembly controls the operation of the hybrid system indicator according to the hybrid system indicator signal received from the hybrid vehicle control ECU via CAN communication.

WIRING DIAGRAM

E370855E25
0.677,2.271 3.042,2.521 2.365,0.25 10 false : CAN Communication Line 0.958,1.583 2.802,2.042 1.844,0.458 10 false Hybrid Vehicle Control ECU 4.677,1.563 6.656,1.969 1.979,0.406 10 false Combination Meter Assembly

CAUTION / NOTICE / HINT

NOTICE:
·

When replacing the combination meter assembly, always replace it with a new one. If a combination meter assembly which was installed to another vehicle is used, the information stored in it will not match the information from the vehicle and a DTC may be stored.

-

Combination meter assembly

-

Hybrid vehicle control ECU


·

Before replacing the hybrid vehicle control ECU, refer to Service Bulletin.



PROCEDURE

2.CHECK FOR DTC (HYBRID CONTROL SYSTEM)
a.

Check if hybrid control system DTCs are output.

Powertrain > Hybrid Control > Trouble Codes
50001 397

Result:
Result Proceed to
DTCs are not output A
DTCs are output B



A

3.PERFORM ACTIVE TEST USING GTS

B

3.PERFORM ACTIVE TEST USING GTS
a.

Perform the Active Test according to the display on the GTS.

Body Electrical > Combination Meter > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
HV/EV System Indicator (MIN) Hybrid system indicator value
(Charge area lower limit)
ON See [Display 1]
HV/EV System Indicator (-50%) Hybrid system indicator value
(Charge area)
ON See [Display 1]
HV/EV System Indicator (0%) Hybrid system indicator value
(Charge area/eco area boundary)
ON See [Display 1]
HV/EV System Indicator (100%) Hybrid system indicator value
(Eco area/power area boundary)
ON See [Display 1]
HV/EV System Indicator (200%) Hybrid system indicator value
(Power area)
ON See [Display 1]
HV/EV System Indicator (300%) Hybrid system indicator value
(Power area)
ON See [Display 1]
HV/EV System Indicator (400%) Hybrid system indicator value
(Power area)
ON See [Display 1]
HV/EV System Indicator (MAX) Hybrid system indicator value
(Power area upper limit)
ON See [Display 1]
[Display 1]: HV/EV System Indicator
E483845C01
1.938,2.177 1.927,0.646 true 1.875,2.208 0.292,2.24 true 1.896,2.25 0.635,3.01 true 1.906,2.208 1.094,0.896 true 1.938,2.219 2.344,0.698 true 2.729,0.854 1.938,2.25 true 1.927,2.198 1.521,0.75 true 1.906,2.229 0.427,2.667 true 0.479,2.99 0.635,3.188 0.156,0.198 10 false 1 0.281,2.646 0.438,2.844 0.156,0.198 10 false 2 0.146,2.167 0.302,2.365 0.156,0.198 10 false 3 0.99,0.781 1.146,0.979 0.156,0.198 10 false 4 1.448,0.583 1.604,0.781 0.156,0.198 10 false 5 1.885,0.49 2.042,0.688 0.156,0.198 10 false 6 2.333,0.531 2.49,0.729 0.156,0.198 10 false 7 2.76,0.708 2.917,0.906 0.156,0.198 10 false 8 0.219,0.25 0.531,0.448 0.313,0.198 10 false *a
*a Hybrid System Indicator


HINT:

Refer to the following table for the specified hybrid system indicator position for each selected value:

Tester Display Hybrid System Indicator Indication
HV/EV System Indicator
(MIN)
Approximately 1 is indicated
HV/EV System Indicator
(-50%)
Approximately 2 is indicated
HV/EV System Indicator
(0%)
Approximately 3 is indicated
HV/EV System Indicator
(100%)
Approximately 4 is indicated
HV/EV System Indicator
(200%)
Approximately 5 is indicated
HV/EV System Indicator
(300%)
Approximately 6 is indicated
HV/EV System Indicator
(400%)
Approximately 7 is indicated
HV/EV System Indicator
(MAX)
Approximately 8 is indicated



Body Electrical > Combination Meter > Active Test
Tester Display
HV System Indicator (MIN)
50004 409 256
Body Electrical > Combination Meter > Active Test
Tester Display
HV System Indicator (-50%)
50004 409 257
Body Electrical > Combination Meter > Active Test
Tester Display
HV System Indicator (0%)
50004 409 258
Body Electrical > Combination Meter > Active Test
Tester Display
HV System Indicator (100%)
50004 409 259
Body Electrical > Combination Meter > Active Test
Tester Display
HV System Indicator (200%)
50004 409 260
Body Electrical > Combination Meter > Active Test
Tester Display
HV System Indicator (300%)
50004 409 261
Body Electrical > Combination Meter > Active Test
Tester Display
HV System Indicator (400%)
50004 409 262
Body Electrical > Combination Meter > Active Test
Tester Display
HV System Indicator (MAX)
50004 409 263

Result:
Result Proceed to
Active Test can be performed correctly A
Active Test cannot be performed correctly B



A

B