HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model)  Front Window Fogging  


DESCRIPTION

If the windshield frequently fogs up even though the air conditioning system is operating, the following factors may be the cause.

Symptom Factor
Windshield frequently fogs up
·

Compressor assembly with pulley malfunction

·

Refrigerant volume (low)

·

Cooler expansion valve (opened excessively)

·

Damper servo malfunction

·

Mechanical locking of damper and damper link



PROCEDURE

1.CHECK REFRIGERANT SHORTAGE
a.

Prepare the vehicle according to the table below.

Measurement Condition:
Item Condition
A/C Switch On
Ambient Temperature*1 0 to 49°C (32 to 120°F)
Air Conditioning Air Inlet Temperature*2 25 to 35°C (77 to 95°F)
Set Temperature MAX COLD
Recirculation/fresh Control Switch Recirculation
Air Vent Damper Position FACE
Blower Speed HI

HINT:

*1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.

*2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.



b.

Using the GTS, check the amount of refrigerant.

Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Gas Volume Check
50005 450 4578
NOTICE:

If the conditions for the inspection are not met, "Refrigerant incorrect" will be displayed on the GTS. Confirm the conditions of the inspection and perform the check again.


HINT:
·

If the amount of refrigerant is insufficient, "Refrigerant shortage" is displayed on the GTS and the indicator light on the A/C switch turns off.

·

When performing this inspection, a DTC will not be output even if "Refrigerant shortage" is displayed on the GTS.



Result:
Result Amount of Refrigerant
Refrigerant shortage Insufficient or leakage
Refrigerant correct Correct
Refrigerant incorrect Incorrect


OK:

"Refrigerant correct" is displayed on the GTS.



Result:
Proceed to
OK
NG



OK

2.CHECK OPERATION

NG

2.CHECK OPERATION
a.

Check that the air conditioning system changes to DEF mode according to the switch operation, when the MODE switch on the air conditioning control assembly is pushed.

OK:

Air conditioning system changes to DEF mode.



Result:
Proceed to
OK
NG



OK

NG