The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors its internal operation and will store DTCs if it detects a malfunction. If any of the following DTCs are output, replace the inverter with converter assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | Note |
|---|---|---|---|---|---|---|
| P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
SAE Code:
P06B0 |
| P0A1A49 | Generator Control Module Internal Electronic Failure | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
SAE Code:
P0A1A |
| P0A1B47 | Drive Motor "A" Control Module Watchdog / Safety MC Failure | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
SAE Code:
P0A1B |
| P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
SAE Code:
P0A1B |
| P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
SAE Code:
P1C2A |
| P1C2A71 | Generator A/D Converter Circuit Actuator Stuck | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
SAE Code:
P1C2A |
| P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
SAE Code:
P1C2B |
| P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
SAE Code:
P1C2B |
| P1C2B71 | Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
SAE Code:
P1C2B |
| P1C601F | Generator Control Module Position Sensor REF Power Source Circuit Intermittent | Motor generator control ECU internal malfunction detected when DTC P0C7917, P0E5717, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic) |
Inverter with converter assembly | Does not come on | Master Warning:
Does not come on |
SAE Code:
P1C60 |
| P1C621F | Generator Control Module Offset Power Circuit Intermittent | Motor generator control ECU internal malfunction detected when DTC P0C7917, P0E5717, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic) |
Inverter with converter assembly | Does not come on | Master Warning:
Does not come on |
SAE Code:
P1C62 |
| P26DF1C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
SAE Code:
P26DF |
| P26DF1F | Generator Control Module Position Sensor REF Power Source Circuit Intermittent | Motor generator control ECU internal malfunction detected when DTC P0C7917, P0E5717, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic) |
Inverter with converter assembly | Does not come on | Master Warning:
Does not come on |
SAE Code:
P19F7 |
| P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
SAE Code:
P3133 |
| P313386 | Communication Error from Generator to Drive Motor "A" Signal Invalid | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
SAE Code:
P3133 |
| P313387 | Communication Error from Generator to Drive Motor "A" Missing Message | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
SAE Code:
P3133 |
| P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
SAE Code:
P3134 |
| P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
SAE Code:
P3134 |
| P313487 | Communication Error from Drive Motor "A" to Generator Missing Message | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning:
Comes on |
SAE Code:
P3134 |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and wait for 15 seconds or more. [*1]
[*1]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform the normal judgment procedure again.
| Proceed to |
|---|
| NEXT |
NEXT