If recirculation/fresh mode changes unintentionally and without permission, the following causes are possible.
| Symptom | Factor |
|---|---|
·
Recirculation/fresh mode changes without permission ·
Recirculation/fresh mode light blinks |
·
Change in ambient air temperature ·
Decrease in refrigerant pressure ·
Air conditioning pressure sensor circuit malfunction ·
Engine coolant temperature (high) |
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ambient Temperature Sensor | Ambient temp. sensor (thermistor assembly) | -327.68 to 327.67°C | Actual ambient temperature displayed | Ambient temp. sensor (thermistor assembly) circuit malfunction |
| Tester Display |
|---|
| Ambient Temperature Sensor |
The value of the display does not change frequently.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F)
Max.: 140°C (284°F) |
75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature.
|
| Tester Display |
|---|
| Coolant Temperature |
The value of the display does not change frequently.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Install a manifold gauge set.
Prepare the vehicle according to the table below.
| Item | Condition |
|---|---|
| Doors | Fully open |
| A/C Switch | On |
| Recirculation/fresh Control Switch | Recirculation |
| Set Temperature | MAX COLD |
| Blower Speed | HI |
| Air Conditioning Air Inlet Temperature | 25 to 35°C (77 to 95°F) |
Compare the values displayed in the Data List and on the manifold gauge.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioning pressure sensor | -32.768 to 32.767 MPaG | Actual refrigerant pressure displayed | ·
Refrigerant line (gas leak etc.) ·
Air conditioning pressure sensor circuit malfunction |
| Tester Display |
|---|
| Regulator Pressure Sensor |
The values displayed in the Data List and on the manifold gauge match.
| Proceed to |
|---|
| OK |
| NG |
OK
NG