If cool air is not discharged (air is discharged), the following malfunctions are possible.
| Malfunction Status | Factor |
|---|---|
| for Front:
Cool air is not discharged. (Air is discharged.) |
·
Compressor with magnet clutch assembly malfunction ·
Refrigerant pressure malfunction ·
Lack of refrigerant gas ·
Dirty cooler condenser ·
Cooling fan system malfunction ·
Air mix damper and link operation (jamming) ·
No. 1 cooler thermistor (determined as cold, conflicting with actual temperature) ·
Warm air flow |
| for Rear:
Cool air is not discharged. (Air is discharged.) (for Rear Automatic Air Conditioning) |
·
Air mix damper and link operation (jamming) ·
No. 2 cooler thermistor (determined as cold, conflicting with actual temperature) ·
Cooler expansion valve ·
Warm air flow |
| Result | Proceed to |
|---|---|
| for Front | A |
| for Rear (w/ Integration Control Panel (for Rear Automatic Air Conditioning)) | B |
A
B
Operate each switch on the air conditioning control assembly to check that the switch indicators are illuminated normally.
Switch indicators are illuminated normally.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse | Min.: 128
Max.: 383 |
Operates between 165 to 257 pulses |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
Damper servo motor is operated.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Operate each switch on the integration control and panel assembly to check that the switch indicators are illuminated normally.
Switch indicators are illuminated normally.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Rear Air Mix Servo Targ Pulse | No. 1 rear cooling unit damper servo motor sub-assembly (rear air mix) pulse | Min.: 128
Max.: 383 |
Operates between 254 and 299 pulses |
Damper servo motor is operated.
| Tester Display |
|---|
| Rear Air Mix Servo Targ Pulse |
| Proceed to |
|---|
| OK |
| NG |
OK
NG