RM35X0E _58 Vehicle Interior _079316 HEATING / AIR CONDITIONING _0386653 AIR CONDITIONING SYSTEM(for Manual Cooler System) J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Cooler System)  Front Window Fogging  


DESCRIPTION

If the front glass frequently fogs up when the air conditioning system is operated, the following causes are possible.

Malfunction Status Factor
Front glass frequently fogs.
·

Compressor with magnet clutch assembly malfunction

·

Lack of refrigerant gas

·

Cooler expansion valve (opened too far)



PROCEDURE

1.CHECK REFRIGERANT SHORTAGE
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.

Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Gas Volume Check
50005 121 3186

e.

Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.

Measurement Condition:
Item Condition
Vehicle Condition Engine running
Temperature Switch On
Ambient temperature*1 0 to 49°C (32 to 120°F)
Air Conditioning Air Inlet Temperature*2 25 to 35°C (77 to 95°F)
Set Temperature MAX COLD
Recirculation/fresh Control Switch Recirculation
Air Vent Damper Position FACE
Blower Speed HI

HINT:
·

Refer to the GTS operator's manual for further details.

·

A message indicating a refrigerant shortage is displayed on the GTS and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.

·

DTCs are not stored when performing the refrigerant shortage check using the GTS.

·

*1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.

·

*2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.



Result:
Result Amount of Refrigerant
Refrigerant shortage Insufficient or leakage
Refrigerant correct Correct


OK:

"Refrigerant correct" is displayed on the GTS.



Result:
Proceed to
OK
NG



OK

2.CHECK OPERATION

NG

2.CHECK OPERATION
a.

When the MODE switch on the air conditioning control assembly operated, check that the air conditioning system changes to DEF mode according to the switch operation.

OK:

Air conditioning system changes to DEF mode.



Result:
Proceed to
OK
NG



OK

NG

3.INSPECT NO. 1 HEATER CONTROL SUB-ASSEMBLY
4.CHECK MODE DAMPER CONTROL CABLE SUB-ASSEMBLY

b.

Check if the same malfunction recurs.

OK:

Malfunction does not reoccur (returns to normal).



Result:
Proceed to
OK
NG



OK

END (MODE DAMPER CONTROL CABLE SUB-ASSEMBLY WAS DEFECTIVE)

NG

REPAIR OR REPLACE AIR CONDITIONING RADIATOR ASSEMBLY