| DTC No. | Detection Item | DTC Detection Condition | Link |
|---|---|---|---|
| B1412 | Ambient Temperature Sensor Circuit | ·
Diagnosis condition: None ·
Malfunction status: Open or short in ambient temperature sensor circuit ·
Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction) |
201902,999999,_58,_079316,_0386653,RM100000001GYY2,B1412
|
| B1413 | Evaporator Temperature Sensor Circuit | ·
Diagnosis condition: None ·
Malfunction status: Open or short in evaporator temperature sensor circuit ·
Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction) |
201902,999999,_58,_079316,_0386653,RM100000001GYY4,B1413
|
| B1417 | Evaporator Temperature Circuit | ·
Diagnosis condition: None ·
Malfunction status: Open or short in evaporator temperature sensor circuit ·
Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction) |
201902,999999,_58,_079316,_0386653,RM100000001HWJG,B1417
|
| B1422 | Compressor Lock Sensor Circuit | Open or short in A/C lock sensor circuit
·
Diagnosis condition: Cooler compressor assembly operating ·
Malfunction status: Open or short in cooler compressor circuit ·
Detection time: None (Present malfunction), continuously for 3 seconds or more (Past malfunction) |
201902,999999,_58,_079316,_0386653,RM100000001GZXI,B1422
|
| B1423 | Pressure Sensor Circuit | ·
Diagnosis condition: Ignition switch ON ·
Malfunction Status: Refrigerant pressure signal malfunction ·
Detection time: Continuously for 4 seconds or more (Present malfunction) |
201902,999999,_58,_079316,_0386653,RM100000001GZXJ,B1423
|
| B14A2 | Driver Side Solar Sensor Short Circuit | Short in cooler thermistor (solar sensor) circuit | 201902,999999,_58,_079316,_0386653,RM100000001GYYM,B14A2
|
| B14B8 | Refrigerant Shortage | ·
Diagnosis condition: The amount of refrigerant is judged to be insufficient in normal operation ·
Malfunction status: When following condition is detected in refrigerant shortage check in normal operation; Amount of refrigerant is insufficient ·
Detection time: During air conditioning system operation for 10 minutes or more |
201902,999999,_58,_079316,_0386653,RM100000001GYYO,B14B8
|
| U0100 | Lost Communication with ECM / PCM "A" | No communication with ECM | 201902,999999,_58,_079316,_0386653,RM100000001GYYS,U0100
|
| U0142 | Lost Communication with Body Control Module "B" | No communication with main body ECU (multiplex network body ECU) | 201902,999999,_58,_079316,_0386653,RM100000001GYYS,U0100
|
| U0155 | Lost Communication with Instrument Panel Cluster (IPC) Control Module | No communication with combination meter assembly | 201902,999999,_58,_079316,_0386653,RM100000001GYYS,U0100
|