HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM  P1CFF62  Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure  


DTC SUMMARY

MALFUNCTION DESCRIPTION


If there is a large difference between the reactor current sensor value and the HV battery current sensor value, a malfunction will be detected.

Internal inverter malfunction
·

Current sensor malfunction

·

Inverter with converter assembly internal circuit malfunction



DESCRIPTION

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate Note
P1CFF62 Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure The difference between the reactor current sensor value and the HV battery current sensor value is large.
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Comes on Master Warning:
Comes on
SAE Code:
P1CFF

MONITOR DESCRIPTION

If the motor generator control ECU detects a large difference between the reactor current sensor value and battery current sensor value, it will illuminate the MIL and store a DTC.

MONITOR STRATEGY

Related DTCs P1CFF (INF P1CFF62): Hybrid/EV Battery Current/DC/DC Converter Current Correlation
Required sensors/components DC/DC Converter Current Sensor Circuit
Frequency of operation Continuous
Duration TMC's intellectual property
MIL operation 1 driving cycle
Sequence of operation None

TYPICAL ENABLING CONDITIONS

The monitor will run whenever the following DTCs are not stored TMC's intellectual property
Other conditions belong to TMC's intellectual property -

TYPICAL MALFUNCTION THRESHOLDS

TMC's intellectual property -

COMPONENT OPERATING RANGE

Motor generator control ECU DTC P1CFF (INF P1CFF62) is not detected

CONFIRMATION DRIVING PATTERN

HINT:
·

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY



1.

Connect the GTS to the DLC3.

2.

Turn the ignition switch to ON and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the ignition switch off and wait for 2 minutes or more.

5.

Turn the ignition switch to ON and turn the GTS on.

6.

With the ignition switch ON and wait for 5 seconds or more. [*1]

7.

Turn the ignition switch to ON (READY) and wait for 5 seconds or more. [*2]

8.

With the brake pedal depressed, depress the accelerator pedal to start the engine. [*3]

9.

Wait for approximately 10 seconds while depressing the brake pedal and accelerator pedal. [*4]

HINT:

[*1] to [*4]: Normal judgment procedure.

The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.


10.

Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

11.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform the normal judgment procedure again.




CAUTION / NOTICE / HINT

CAUTION:

Refer to the precautions before inspecting high voltage circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION


NOTICE:
·

After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery.

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART




HINT:

P1CFF62 may be output as a result of the malfunction indicated by the DTCs in table below.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)



Table 1
Malfunction Content System Relevant DTC
Insulation Malfunction Hybrid control system P1C7C49 Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure
P1C7D49 Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure
P1C7E49 Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure
P1C7F49 Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure
P1C8049 Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure
HV Battery Malfunction Hybrid control system P0ABF00 Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance
P0ABF11 Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground
P0ABF15 Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open
P0ABF28 Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure
P0ABF2A Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range
P1CBB12 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery
P1CBB14 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open
P060687 Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message
P060A47 Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure
P060A87 Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message
P060B49 Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure
U011187 Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message
Hybrid battery system P0B0E11 Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground
P0B0E15 Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open
P0B1362 Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure
P0E2D00 Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance

Table 2
Malfunction Content System Relevant DTC
Microcomputer malfunction Motor generator control system P0A1A47 Generator Control Module Watchdog / Safety MC Failure
P0A1A49 Generator Control Module Internal Electronic Failure
P0A1B1F Generator Control Module Circuit Intermittent
P0A1B47 Drive Motor "A" Control Module Watchdog / Safety MC Failure
P1C2A1C Generator A/D Converter Circuit Circuit Voltage Out of Range
P1C2A49 Generator A/D Converter Circuit Internal Electronic Failure
P1C2A71 Generator A/D Converter Circuit Actuator Stuck
P1C2B1C Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range
P1C2B49 Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure
P1C2B71 Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck
P313383 Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect
P313386 Communication Error from Generator to Drive Motor "A" Signal Invalid
P313387 Communication Error from Generator to Drive Motor "A" Missing Message
P313483 Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect
P313486 Communication Error from Drive Motor "A" to Generator Signal Invalid
P313487 Communication Error from Drive Motor "A" to Generator Missing Message
Hybrid control system P0A1B49 Drive Motor "A" Control Module Internal Electronic Failure
Power source circuit malfunction Motor generator control system P06B01C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P06D61C Generator Control Module Offset Power Circuit Voltage Out of Range
P19F81C Generator Control Module Offset Power Circuit Voltage Out of Range
P26DF1C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
Communication malfunction Motor generator control system U11B387 Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Missing Message
Hybrid control system U117E87 Lost Communication with Drive Motor Control Module "A" (ch4) MissingMessage
Sensor and actuator circuit malfunction Motor generator control system P0E5111 DC/DC Converter Current Sensor Circuit Short to Ground
P0E5115 DC/DC Converter Current Sensor Circuit Short to Battery or Open
P0E5128 DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure


PROCEDURE

1.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P033506

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR