MALFUNCTION DESCRIPTION
If there is a large difference between the reactor current sensor value and the HV battery current sensor value, a malfunction will be detected.
Current sensor malfunction
Inverter with converter assembly internal circuit malfunction
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | Note |
|---|---|---|---|---|---|---|
| P1CFF62 | Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure | The difference between the reactor current sensor value and the HV battery current sensor value is large.
(1 trip detection logic) |
·
Inverter with converter assembly ·
Wire harness or connector |
Comes on | Master Warning:
Comes on |
SAE Code:
P1CFF |
If the motor generator control ECU detects a large difference between the reactor current sensor value and battery current sensor value, it will illuminate the MIL and store a DTC.
| Related DTCs | P1CFF (INF P1CFF62): Hybrid/EV Battery Current/DC/DC Converter Current Correlation |
| Required sensors/components | DC/DC Converter Current Sensor Circuit |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not stored | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| TMC's intellectual property | - |
| Motor generator control ECU | DTC P1CFF (INF P1CFF62) is not detected |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and turn the GTS on.
With the ignition switch ON and wait for 5 seconds or more. [*1]
Turn the ignition switch to ON (READY) and wait for 5 seconds or more. [*2]
With the brake pedal depressed, depress the accelerator pedal to start the engine. [*3]
Wait for approximately 10 seconds while depressing the brake pedal and accelerator pedal. [*4]
[*1] to [*4]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform the normal judgment procedure again.
Refer to the precautions before inspecting high voltage circuit.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
When disconnecting and reconnecting the auxiliary battery.
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
P1CFF62 may be output as a result of the malfunction indicated by the DTCs in table below.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Insulation Malfunction | Hybrid control system | P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | ||
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | ||
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure | ||
| P1C8049 | Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure | ||
| HV Battery Malfunction | Hybrid control system | P0ABF00 | Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance |
| P0ABF11 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground | ||
| P0ABF15 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open | ||
| P0ABF28 | Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0ABF2A | Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range | ||
| P1CBB12 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery | ||
| P1CBB14 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open | ||
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message | ||
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message | ||
| P060B49 | Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure | ||
| U011187 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message | ||
| Hybrid battery system | P0B0E11 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground | |
| P0B0E15 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open | ||
| P0B1362 | Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure | ||
| P0E2D00 | Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance | ||
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Motor generator control system | P0A1A47 | Generator Control Module Watchdog / Safety MC Failure |
| P0A1A49 | Generator Control Module Internal Electronic Failure | ||
| P0A1B1F | Generator Control Module Circuit Intermittent | ||
| P0A1B47 | Drive Motor "A" Control Module Watchdog / Safety MC Failure | ||
| P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | ||
| P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | ||
| P1C2A71 | Generator A/D Converter Circuit Actuator Stuck | ||
| P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range | ||
| P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure | ||
| P1C2B71 | Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck | ||
| P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect | ||
| P313386 | Communication Error from Generator to Drive Motor "A" Signal Invalid | ||
| P313387 | Communication Error from Generator to Drive Motor "A" Missing Message | ||
| P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect | ||
| P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid | ||
| P313487 | Communication Error from Drive Motor "A" to Generator Missing Message | ||
| Hybrid control system | P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure | |
| Power source circuit malfunction | Motor generator control system | P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range | ||
| P19F81C | Generator Control Module Offset Power Circuit Voltage Out of Range | ||
| P26DF1C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range | ||
| Communication malfunction | Motor generator control system | U11B387 | Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Missing Message |
| Hybrid control system | U117E87 | Lost Communication with Drive Motor Control Module "A" (ch4) MissingMessage | |
| Sensor and actuator circuit malfunction | Motor generator control system | P0E5111 | DC/DC Converter Current Sensor Circuit Short to Ground |
| P0E5115 | DC/DC Converter Current Sensor Circuit Short to Battery or Open | ||
| P0E5128 | DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |