MALFUNCTION DESCRIPTION
These DTCs indicate that the current sensor value is abnormal. The cause of this malfunction may be one of the following:
Current sensor malfunction
Inverter with converter assembly internal circuit malfunction
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | Note |
|---|---|---|---|---|---|---|
| P0DFA62 | Generator Phase U-V-W Current Sensor Signal Compare Failure | Generator inverter current sensor characteristic malfunction:
The value of the total output of the U, V and W phase current sensors exceeds the threshold.*1 (1 trip detection logic) |
·
Inverter with converter assembly ·
Hybrid vehicle transaxle assembly ·
Motor cable ·
Wire harness or connector |
Comes on | Master Warning:
Comes on |
SAE Code:
P0DFA |
| P1C691F | Generator Phase U-V-W Current Sensor Circuit Intermittent | The value of the total output of the U, V and W phase current sensors exceeds the threshold detected when DTC P0C7917, P0E5717, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic) |
·
Inverter with converter assembly ·
Hybrid vehicle transaxle assembly ·
Motor cable ·
Wire harness or connector |
Does not come on | Master Warning:
Does not come on |
SAE Code:
P1C69 |
*1: Under normal conditions, the value of the total output of the U, V and W phase current sensors is approximately 0
If the value of the total output of the U, V and W phase current sensors exceeds a threshold, a malfunction will be detected, the motor generator control ECU will illuminate the MIL and store a DTC.
| Related DTCs | P0DFA (INF P0DFA62): Signal Compare Failure |
| Required sensors/components | Generator Phase U Current Sensor
Generator Phase V Current Sensor Generator Phase W Current Sensor |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not stored | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| TMC's intellectual property | - |
| Motor generator control ECU | DTC P0DAF (INF P0DFA62) is not detected |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and wait for 5 seconds or more. [*1]
Turn the ignition switch to ON (READY) with the shift lever in P and wait for 5 seconds or more. [*2]
Press the HV EV CHG HOLD mode switch to enter HV drive mode. [*3]
Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine. [*4]
Drive the vehicle for approximately 10 minutes referring to the following freeze frame data item: "Vehicle Speed". [*5]
[*1] to [*5]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform the normal judgment procedure again.
Refer to the wiring diagram for the Generator High-voltage Circuit.
Refer to the precautions before inspecting high voltage circuit.
After the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.
When disconnecting and reconnecting the auxiliary battery.
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
P0DFA62 or P1C691F may be output as a result of the malfunction indicated by the DTCs in table below.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Insulation malfunction | Hybrid control system | P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | ||
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | ||
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure | ||
| P1C8049 | Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure | ||
| High voltage circuit malfunction | Hybrid control system | P0AA649 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Motor generator control system | P0A1A47 | Generator Control Module Watchdog / Safety MC Failure |
| P0A1A49 | Generator Control Module Internal Electronic Failure | ||
| P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | ||
| P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | ||
| P1C2A71 | Generator A/D Converter Circuit Actuator Stuck | ||
| P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect | ||
| P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid | ||
| P313487 | Communication Error from Drive Motor "A" to Generator Missing Message | ||
| Power source circuit malfunction | Motor generator control system | P19F81C | Generator Control Module Offset Power Circuit Voltage Out of Range |
| P26DF1C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range | ||
| Communication malfunction | Motor generator control system | U11B387 | Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Missing Message |
| System malfunction | Motor generator control system | P0A7A73 | Generator Inverter Actuator Stuck Closed |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
If the "Generator High-voltage Circuit" inspection results are normal, perform the next step.
| Proceed to |
|---|
| NEXT |
NEXT