If warm air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause.
| Symptom | Factor |
|---|---|
| No cool air comes out
(Blower control is normal) |
·
Compressor with pulley assembly malfunction ·
Refrigerant pressure is extremely high or low ·
Refrigerant volume (low) ·
Clogged cooler condenser assembly fins ·
Cooling fan system malfunction ·
Mechanical locking of damper and damper link ·
No. 1 cooler thermistor malfunction ·
High inlet air temperature |
Operate each switch on the air conditioning control assembly and check that the switch indicators operate normally.
All switch indicators operate normally.
| Proceed to | |
|---|---|
| OK (for Dual Type) | A |
| OK (for Single Type) | B |
| NG | C |
A
B
C
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Front Left Air Mix Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 384 |
Operates between 165 to 257 pulses |
| Front Right Air Mix Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 384 |
Operates between 255 to 347 pulses |
| Active Test Display |
|---|
| Front Left Air Mix Damper Control Servo Motor |
| Data List Display |
|---|
| Front Left Air Mix Damper Control Servo Motor Actual Pulse |
| Active Test Display |
|---|
| Front Right Air Mix Damper Control Servo Motor |
| Data List Display |
|---|
| Front Right Air Mix Damper Control Servo Motor Actual Pulse |
The No. 1 air conditioning radiator damper servo motor operates.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Front Air Mix Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 384 |
Operates between 165 to 257 pulses |
| Active Test Display |
|---|
| Front Air Mix Damper Control Servo Motor |
| Data List Display |
|---|
| Front Air Mix Damper Control Servo Motor Actual Pulse |
The No. 1 air conditioning radiator damper servo motor operates.
| Proceed to |
|---|
| OK |
| NG |
OK
NG