If recirculation/fresh mode changes unintentionally and without permission, the following causes are possible.
| Symptom | Factor |
|---|---|
·
Recirculation/fresh mode changes without permission ·
Recirculation/fresh mode light blinks |
·
Customize setting ·
Change in ambient air temperature ·
Decrease in refrigerant pressure ·
Air conditioner pressure sensor circuit malfunction ·
Engine coolant temperature (high) |
Using the GTS, check that the customize setting Air Inlet Mode is not set to "Automatic".
| Tester Display | Description | Default | Setting | ECU |
|---|---|---|---|---|
| Efficient Ventilation Mode | Function to change the mode automatically to recirculation air mode when turning the A/C on to cool the cabin quickly | ON | $00:OFF,$01:ON | Air conditioning amplifier assembly |
Air Inlet Mode is not set to "Automatic".
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Set Air Inlet Mode to "Manual"
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ambient Temperature Sensor | Thermistor assembly | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual ambient temperature displayed | Thermistor assembly circuit malfunction |
| Tester Display |
|---|
| Ambient Temperature Sensor |
The value of the display does not change frequently.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F), Max.: 140°C (284°F) | 75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature.
|
| Tester Display |
|---|
| Coolant Temperature |
The value of the display does not change frequently.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -32768 MPaG
Max.: 32767 MPaG |
Actual refrigerant pressure displayed | Refrigerant line (gas leak etc.)
·
Refrigerant line (gas leak etc.) ·
Air conditioner pressure sensor circuit malfunction |
| Tester Display |
|---|
| Regulator Pressure Sensor |
Install a manifold gauge set.
Read the manifold gauge pressure when the following conditions are met.
Prepare the vehicle according to the table below.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi)
1370 to 1570 kPa (14 to 16 kgf/cm2, 199 to 228 psi)
Compare the values displayed in the Data List and on the manifold gauge.
The values displayed in the Data List and on the manifold gauge match.
| Proceed to |
|---|
| OK |
| NG |
OK
NG