The compressor with pulley assembly receives refrigerant compression demand signals from the air conditioning amplifier assembly.
Based on this signal, the compressor with pulley assembly changes the amount of compressor output.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P06A014 | Compressor Solenoid Circuit Short to Ground or Open | Diagnosis Condition:
Compressor with pulley assembly operating Malfunction Status:
Open or short in compressor solenoid circuit Detection Time:
Continuously for 30 seconds or more |
·
Compressor with pulley assembly ·
Harness or connector ·
Air conditioning amplifier assembly |
Memorized | Air Conditioner | A |
| Vehicle Condition | |||
|---|---|---|---|
| Pattern 1 | Pattern 2 | ||
| Diagnosis Condition | compressor with pulley assembly operating | ○ | ○ |
| Malfunction Status | Open in compressor solenoid circuit | ○ | - |
| Short in compressor solenoid circuit | - | ○ | |
| Detection Time | Continuously for 30 seconds or more | Continuously for 30 seconds or more | |
If the conditions of either of these patterns are detected, a DTC will be stored.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Solenoid Valve Control Current Value | Solenoid valve control current | Min.: 0 mA
Max.: 1000 mA |
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation | - |
| Tester Display |
|---|
| Solenoid Valve Control Current Value |
The display is as specified in the normal condition column.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Disconnect the C44 compressor with pulley assembly connector.
Procedure1
| *a | Component without harness connected
(Compressor with Pulley Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (SOL-) - 2 (SOL+) | Compressor temperature 25°C (77°F) | 10.1 to 11.1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the C44 compressor with pulley assembly connector.
Disconnect the G46 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C44-2 (SOL+) - G46-18 (SOL+) | Always | Below 1 Ω |
| C44-1 (SOL-) - Body ground | Always | Below 1 Ω |
| C44-2 (SOL+) or G46-18 (SOL+) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG