RM36D0EC _58 Vehicle Interior _083104 HEATING / AIR CONDITIONING _0402828 AIR CONDITIONING SYSTEM(for Gasoline Model) U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model)  DATA LIST / ACTIVE TEST  


DATA LIST


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


a.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Total Distance Traveled Total driving distance 0 to 999999 Actual total driving distance -
Total Distance Traveled - Unit Unit of driving distance km or mile - -
Room Temperature Sensor Cabin temperature -327.68 to 327.67 °C Ambient temperature of cooler thermistor (room temperature sensor) Cooler thermistor (room temperature sensor) circuit
(for Automatic Air Conditioning System)
Ambient Temperature Sensor Ambient temperature -327.68 to 327.67 °C Ambient temperature of thermistor assembly Thermistor assembly circuit
Front Left Solar Sensor Front left side automatic light control sensor 0 to 6553.5 W/m2 Automatic light control sensor value increases as brightness increases Automatic light control sensor circuit
(for Automatic Air Conditioning System)
Front Right Solar Sensor Front right side automatic light control sensor 0 to 6553.5 W/m2 Automatic light control sensor value increases as brightness increases Automatic light control sensor circuit
(for Automatic Air Conditioning System)
Engine Coolant Temperature Sensor Engine coolant temperature (for SFI system) -327.68 to 327.67 °C Actual engine coolant temperature displayed
·

SFI system

·

CAN communication system


Evaporator Fin Thermistor Ambient temperature of No. 1 cooler evaporator -327.68 to 327.67 °C Ambient temperature of No. 1 cooler thermistor No. 1 cooler thermistor circuit
Regulator Pressure Sensor Refrigerant gas pressure on high pressure side -32768 to 32767 kPaG Actual refrigerant pressure displayed
·

Refrigerant line(gas leak etc.)

·

Air conditioning pressure sensor circuit


Ambient Temperature Adjustment Value Numeral value of adjusted ambient temperature -327.68 to 327.67 °C Value calibrated to ambient temperature of the thermistor assembly Thermistor assembly circuit
Front Right Air Outlet Temperature Front right side target temperature -327.68 to 327.67 °C Front right side target air outlet temperature displayed
·

MAX COLD: -327.68°C

·

MAX HOT: 327.67°C


Automatic light control sensor circuit
(for Automatic Air Conditioning System)
Front Left Air Outlet Temperature Front left side target temperature -327.68 to 327.67 °C Front left side target air outlet temperature displayed
·

MAX COLD: -327.68°C

·

MAX HOT: 327.67°C


Automatic light control sensor circuit
(for Automatic Air Conditioning System)
Evaporator Target Temperature Evaporator target temperature -327.68 to 327.67 °C Evaporator target temperature displayed No. 1 cooler thermistor circuit
·

When open circuit: -327.68°C (-557.82°F)

·

When short circuit: 327.67°C (621.81°F)


Front Left Air Mix Damper Control Servo Motor Target Pulse No. 1 air conditioning radiator damper servo sub-assembly target pulse Min.: 128
Max.: 384
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly circuit
(for Automatic Air Conditioning System)
Front Left Air Mix Damper Control Servo Motor Actual Pulse No. 1 air conditioning radiator damper servo sub-assembly actual pulse Min.: 128
Max.: 384
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly circuit
(for Automatic Air Conditioning System)
Front Right Air Mix Damper Control Servo Motor Target Pulse No. 1 air conditioning radiator damper servo sub-assembly target pulse Min.: 128
Max.: 384
·

MAX COLD: 255 (pulse)

·

MAX HOT: 347 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly circuit
(for Automatic Air Conditioning System)
Front Right Air Mix Damper Control Servo Motor Actual Pulse No. 1 air conditioning radiator damper servo sub-assembly actual pulse Min.: 128
Max.: 384
·

MAX COLD: 255 (pulse)

·

MAX HOT: 347 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly circuit
(for Automatic Air Conditioning System)
Front Left Air Outlet Damper Control Servo Motor Target Pulse - - - Although the item is displayed on the GTS, it is not applicable to this vehicle
Front Left Air Outlet Damper Control Servo Motor Actual Pulse - - - Although the item is displayed on the GTS, it is not applicable to this vehicle
Front Right Air Outlet Damper Control Servo Motor Target Pulse - - - Although the item is displayed on the GTS, it is not applicable to this vehicle
Front Right Air Outlet Damper Control Servo Motor Actual Pulse - - - Although the item is displayed on the GTS, it is not applicable to this vehicle
Air Inlet Damper Control Servo Motor Target Pulse No. 1 blower damper servo sub-assembly target pulse Min.: 128
Max.: 384
·

Recirculation: 258 (pulse)

·

Fresh: 235 (pulse)


·

Recirculation: 258 (pulse)

·

Fresh: 235 (pulse)


No. 1 blower damper servo sub-assembly circuit
Air Inlet Damper Control Servo Motor Actual Pulse No. 1 blower damper servo sub-assembly actual pulse Min.: 128
Max.: 384
No. 1 blower damper servo sub-assembly circuit
Front Air Mix Damper Control Servo Motor Target Pulse No. 1 air conditioning radiator damper servo sub-assembly target pulse Min.: 128
Max.: 384
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly circuit
(for Manual Air Conditioning System)
Front Air Mix Damper Control Servo Motor Actual Pulse No. 1 air conditioning radiator damper servo sub-assembly actual pulse Min.: 128
Max.: 384
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly circuit
(for Manual Air Conditioning System)
Front Air Outlet Damper Control Servo Motor Target Pulse No. 1 air conditioning radiator damper servo sub-assembly actual pulse Min.: 128
Max.: 384
·

FACE: 256 (pulse)

·

B/L: 267 (pulse)

·

FOOT-R: 297 (pulse)

·

FOOT-D: 305 (pulse)

·

F/D-R: 320 (pulse)

·

D/F: 339 (pulse)

·

DEF or Close: 348 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly circuit
Front Air Outlet Damper Control Servo Motor Actual Pulse No. 1 air conditioning radiator damper servo sub-assembly actual pulse Min.: 128
Max.: 384
·

FACE: 256 (pulse)

·

B/L: 267 (pulse)

·

FOOT-R: 297 (pulse)

·

FOOT-D: 305 (pulse)

·

F/D-R: 320 (pulse)

·

D/F: 339 (pulse)

·

DEF or Close: 348 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly circuit
Front Control Rear Air Outlet Damper Control Servo Motor Target Pulse No. 2 air conditioning radiator damper servo sub-assembly target pulse Min.: 128
Max.: 384
·

FACE: 260 (pulse)

·

FOOT-R, D, O, F/D: 223 (pulse)

·

B/L: 212 (pulse)

·

FOOT-F: 182 (pulse)

·

D/F: 177 (pulse)

·

DEF/S-FLOW: 158 (pulse)


No. 2 air conditioning radiator damper servo sub-assembly circuit
Front Control Rear Air Outlet Damper Control Servo Motor Actual Pulse No. 2 air conditioning radiator damper servo sub-assembly actual pulse Min.: 128
Max.: 384
·

FACE: 260 (pulse)

·

FOOT-R, D, O, F/D: 223 (pulse)

·

B/L: 212 (pulse)

·

FOOT-F: 182 (pulse)

·

D/F: 177 (pulse)

·

DEF/S-FLOW: 158 (pulse)


No. 2 air conditioning radiator damper servo sub-assembly circuit
Solenoid Valve Control Current Value Solenoid valve control current Min.: 0 mA
Max.: 1000 mA
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation -
ECO Switch Integration control and panel assembly (ECO switch) input condition OFF or ON OFF: Integration control and panel assembly (ECO switch) not operated
ON: Integration control and panel assembly (ECO switch) operated and held
Integration control and panel assembly (ECO switch) circuit
Refrigerant Gas Type Refrigerant gas type R134a or Hfo1234yf Refrigerant gas type displayed -
Refrigerant High Pressure History Count Refrigerant high pressure history Min.: 0
Max.: 255
Number of times refrigerant high pressure history stored displayed *1
Refrigerant Low Pressure History Count Refrigerant low pressure history Min.: 0
Max.: 255
Number of times refrigerant low pressure history stored displayed *1
Operation Limit Control History Count Operation limit control history Min.: 0
Max.: 255
Number of times operation limit control history stored displayed *2
Efficient Ventilation Mode Air inlet mode Manual or Automatic Customized value displayed for Automatic Air Conditioning System
Foot/DEF Automatic Blow Up Function Foot/defroster auto mode level OFF or ON Customized value displayed for Automatic Air Conditioning System
Foot/DEF Auto Mode Foot/defroster auto mode OFF or ON Customized value displayed for Automatic Air Conditioning System
ECO Mode Control Function to cancel ECO mode when set to ON OFF or ON Customized value displayed -
Fan Speed Increment Control Fan speed increment control Slow, Normal or Fast Customized value displayed -
Outside Air Mode Auto Switch Function Outside air mode auto switch function OFF or ON Customized value displayed -
S-FLOW Control Auto Function S-FLOW control auto function OFF or ON Customized value displayed for Automatic Air Conditioning System
A/C Auto Switch Mode A/C auto switch mode OFF or ON Customized value displayed for Automatic Air Conditioning System
Evaporator Control Evaporator control Manual or Automatic Customized value displayed -
Ion Generate Control Ion generator control OFF or ON Customized value displayed w/ Ion Generator
Ambient Temperature Adjustment Ambient temperature display adjustment function 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr or 3C incr Customized value displayed -
Set Temperature Shift Shift set temperature -2C / -1C / Normal / +1C / +2C Customized value displayed for Automatic Air Conditioning System
Refrigerant Shortage Check Refrigerant shortage check OFF or ON Customized value displayed -
Blower Level Blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor speed increases Blower motor with fan sub-assembly circuit
A/C Driving Demand A/C control cutoff signal ON / OFF The ECM sends the air conditioning control cutoff signal displayed -
Ion Generator Operation condition of ion generator sub-assembly OFF / ON Status of ion generator displayed w/ Ion Generator
Front Left Air Mix Damper Control Servo Motor Initialization History Count Displays the initialization history count 0 to 255 - for Automatic Air Conditioning System
Front Right Air Mix Damper Control Servo Motor Initialization History Count Displays the initialization history count 0 to 255 - for Automatic Air Conditioning System
Front Left Air Outlet Damper Control Servo Motor Initialization History Count - - - Although the item is displayed on the GTS, it is not applicable to this vehicle
Front Right Air Outlet Damper Control Servo Motor Initialization History Count Displays the initialization history count 0 to 255 - for Automatic Air Conditioning System
Air Inlet Damper Control Servo Motor Initialization History Count Displays the initialization history count 0 to 255 - -
Front Air Mix Damper Control Servo Motor Initialization History Count Displays the initialization history count 0 to 255 - for Manual Air Conditioning System
Front Air Outlet Damper Control Servo Motor Initialization History Count Displays the initialization history count 0 to 255 - for Manual Air Conditioning System
Front Control Rear Air Outlet Damper Control Servo Motor Initialization History Count Displays the initialization history count 0 to 255 - -
Efficient Ventilation Mode (Driver1) - - - Although the item is displayed on the GTS, it is not applicable to this vehicle
A/C Auto Switch Mode (Driver1) - - - Although the item is displayed on the GTS, it is not applicable to this vehicle
Efficient Ventilation Mode (Driver2) - - - Although the item is displayed on the GTS, it is not applicable to this vehicle
A/C Auto Switch Mode (Driver2) - -
-
- Although the item is displayed on the GTS, it is not applicable to this vehicle
Efficient Ventilation Mode (Driver3) - - - Although the item is displayed on the GTS, it is not applicable to this vehicle
A/C Auto Switch Mode (Driver3) - - - Although the item is displayed on the GTS, it is not applicable to this vehicle

Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Coolant Temperature Engine coolant temperature Min.: -40°C (-40°F)
Max.: 215°C (419°F)
75 to 100°C (167 to 212°F): After warming up This is the engine coolant temperature.
HINT:
·

After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).

·

After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.

·

If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.

·

Check if the engine overheats if the value indicated is higher than 135°C (275°F).





ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Level Blower motor with fan sub-assembly operation 0 to 31 -
A/C Driving Demand Compressor with motor assembly OFF / ON -
Ion Generator Ion generator sub-assembly OFF / ON w/ Ion Generator
Front Left Air Mix Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly operation 128 to 384 Operates between 165 to 257 pulses
(for Automatic Air Conditioning System)
Front Right Air Mix Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly operation 128 to 384 Operates between 255 to 347 pulses
(for Automatic Air Conditioning System)
Front Left Air Outlet Damper Control Servo Motor - - Although the item is displayed on the GTS, it is not applicable to this vehicle
Front Right Air Outlet Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly operation 128 to 384 Operates between 234 to 348 pulses
Air Inlet Damper Control Servo Motor No. 1 blower damper servo sub-assembly operation 128 to 384 Operates between 235 to 258 pulses
Front Air Mix Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly operation 128 to 384 Operates between 165 to 257 pulses
(for Manual Air Conditioning System)
Front Air Outlet Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly operation 128 to 384 Operates between 234 to 348 pulses
Fr Control Rear Air Outlet Damper Servo Motor No. 2 air conditioning radiator damper servo sub-assembly operation 128 to 384 Operates between 158 to 260 pulses
Powertrain > Engine > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Control the Engine Cooling Fan Duty Ratio Electric cooling fan motor operation 0 to 100 (%) Perform this test when vehicle is stopped