RM36D0EC _59 Vehicle Exterior _083107 WINDOW / GLASS _0400968 WINDOW DEFOGGER SYSTEM D

WINDOW / GLASS  WINDOW DEFOGGER SYSTEM  DIAGNOSIS SYSTEM  



INSPECT AUXILIARY BATTERY VOLTAGE


a.

Measure the auxiliary battery voltage with the ignition switch off.

Standard voltage:

11 to 14 V


If the voltage is below 11 V, recharge or replace the auxiliary battery.