89419B
1.INSPECT SHIFT STROKE SENSOR
Connect 3 new dry-cell batteries (1.5 V each) in series.
Prepare a magnet or equivalent tool.
Connect a positive (+) lead from the batteries to terminal 2 (VDD) and a negative (-) lead to terminal 3 (GND).
| *a | Component without harness connected
(Shift Stroke Sensor) |
*b | Magnet Movement Direction |
| *c | Dry Cell Battery | *d | Magnet |
| *e | 2.6 mm (0.102 in.) or less | - | - |
Wave the magnet left and right 2.6 mm (0.102 in.) or less from the tip of the shift stroke sensor to output a high/low signal while measuring the voltage.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C39-4 (VOUT) - C39-3 (GND) | High voltage | 4.09 to 4.19 V |
| Low voltage | 0.36 to 0.45 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C39-4 (VOUT) - C39-3 (GND) | High voltage | 4.55 to 4.65 V |
| Low voltage | 0.4 to 0.5 V |
If the result is not as specified, replace the shift stroke sensor.