1. OPERATION CHECK
Disconnect No. 1 vacuum hose connector.
| *a | Vacuum Gauge |
| *b | Plug |
Connect the hose of the vacuum gauge to the vacuum pump assembly.
Start the engine and warm it up for more than 2 minutes.
With the engine idling, check the vacuum of the vacuum pump assembly.
More than 86.7 kPa (650 mmHg, 25.6 in.Hg)
except BOSCH Made:
If the pressure is less than the standard, disassemble and inspect the vacuum pump. If necessary, replace the vacuum pump assembly.
Always perform this operation check procedure after replacing the vacuum pump assembly.
for BOSCH Made:
If the pressure is less than the standard, replace the vacuum pump assembly.
Remove the vacuum gauge from the vacuum pump assembly.
Connect No. 1 vacuum hose connector.