RM38N0EC _V1 General _111784 SPECIFICATIONS _0499465 M20C-FKS, M20D-FKS STARTING F

SPECIFICATIONS  M20C-FKS, M20D-FKS STARTING  SERVICE DATA  


Starter Assembly (for 1.7 kW Type)
Tester Connection Condition Specified Condition
Battery positive (+) terminal - Terminal 30 - Terminal 50 11.5 V Below 100 A

Magnet Starter Switch Assembly
Tester Connection Condition Specified Condition
Terminal 50 - Terminal C Always Below 1 Ω
Terminal 50 -Magnet starter switch assembly body Below 2 Ω

Starter Armature Assembly (for 1.7 kW Type)
Tester Connection Condition Specified Condition
Segment - Segment Always Below 1 Ω
Segment - Starter armature core 10 kΩ or higher

Commutator for runout Maximum Runout 0.05 mm (0.00197 in.)

Commutator diameter Standard Diameter 29 mm (1.142 in.)
Minimum Diameter 28 mm (1.102 in.)

Undercut depth Standard Undercut Depth 0.7 mm (0.0276 in.)
Minimum Undercut Depth 0.4 mm (0.0157 in.)

Starter Brush Holder Assembly (for 1.7 kW Type)
Brush length Standard Length 14.4 mm (0.567 in.)
Minimum Length 9.0 mm (0.354 in.)

Tester Connection Condition Specified Condition
A - B
A - C
B - D
C - D
Always 10 kΩ or higher
A - D
B - C
Below 1 Ω

Brush spring load Standard Spring Load 22.3 to 27.3 N (2.27 to 2.78 kgf, 5.01 to 6.14 lbf)
Minimum Spring Load 13.8 N (1.41 kgf, 3.1 lbf)

Engine Switch
Tester Connection Condition Specified Condition
12 (SS1) - 3 (GND)
6 (SS2) - 3 (GND)
11 (SS3) - 3 (GND)
Not pushed 10 kΩ or higher
Pushed Below 1 Ω
Auxiliary battery positive (+) → Terminal 5 (SWIL)
Auxiliary battery negative (-) → Terminal 3 (GND)
Illuminates

ST NO. 1 Relay
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω