1.INSPECT SHIFT LEVER POSITION SENSOR
| *a | Component without harness connected
(Shift Lever Position Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 6 (+B) - 2 (P) | Shift lever in P | Below 1 Ω |
| 6 (+B) - 7 (PR) | Below 1 Ω | |
| 6 (+B) - 4 (PNB) | Below 1 Ω | |
| 6 (+B) - 1 (R), 8 (N), 3 (DB1) or 9 (DB2) | 10 kΩ or higher | |
| 6 (+B) - 7 (PR) | Shift lever in R | Below 1 Ω |
| 6 (+B) - 1 (R) | Below 1 Ω | |
| 6 (+B) - 2 (P), 8 (N), 3 (DB1), 9 (DB2) or 4 (PNB) | 10 kΩ or higher | |
| 6 (+B) - 8 (N) | Shift lever in N | Below 1 Ω |
| 6 (+B) - 4 (PNB) | Below 1 Ω | |
| 6 (+B) - 2 (P), 7 (PR), 1 (R), 3 (DB1) or 9 (DB2) | 10 kΩ or higher | |
| 6 (+B) - 3 (DB1) | Shift lever in D or M | Below 1 Ω |
| 6 (+B) - 9 (DB2) | Below 1 Ω | |
| 6 (+B) - 2 (P), 7 (PR), 1 (R), 8 (N) or 4 (PNB) | 10 kΩ or higher |
The shift lever position sensor connector (shift lever position sensor side) does not have a terminal 5.
If the result is not as specified, replace the shift lever position sensor.