RM38N0EC _51 Engine / Hybrid System _111791 M20C-FKS, M20D-FKS COOLING _0503630 FLOW SHUTTING VALVE(for CVT) A

M20C-FKS, M20D-FKS COOLING  FLOW SHUTTING VALVE(for CVT)  INSTALLATION  


PROCEDURE

Hide 16671 1.INSTALL FLOW SHUTTING VALVE (WATER VALVE)

a.

Connect the No. 2 water by-pass hose to the flow shutting valve (water valve) and slide the clip to secure it.

A478269C01
1.927,0.125 2.24,0.281 0.313,0.156 10 false *a 2.417,1.448 2.729,1.604 0.313,0.156 10 false *b 2.427,0.125 2.74,0.281 0.313,0.156 10 false *c 0.688,0.938 1,1.094 0.313,0.156 10 false *d 5.552,1.229 5.708,1.427 0.156,0.198 10 true A
*a View A *b 120° (Tabs of Clip Installation Area)
*c Upper Side of Vehicle *d 2 to 5 mm (0.0787 to 0.197 in.)


NOTICE:
·

Make sure to slide the No. 2 water by-pass hose until it contacts the hose stopper of the flow shutting valve (water valve).

·

Make sure that the tabs of the clip are within the area shown in the illustration.




b.

Connect the No. 4 water by-pass hose to the flow shutting valve (water valve) and slide the clip to secure it.

A478270C01
1.688,0.115 2,0.271 0.313,0.156 10 false *a 2.438,0.167 2.75,0.323 0.313,0.156 10 false *b 2.438,0.417 2.75,0.573 0.313,0.156 10 false *c 1.802,1.021 2.115,1.177 0.313,0.156 10 false *d 5.823,0.25 6.083,0.5 0.26,0.25 10 true A
*a View A *b 120° (Tabs of Clip Installation Area)
*c Upper Side of Vehicle *d 2 to 7 mm (0.0787 to 0.276 in.)


NOTICE:
·

Make sure to slide the No. 4 water by-pass hose until it contacts the hose stopper of the flow shutting valve (water valve).

·

Make sure that the tabs of the clip are within the area shown in the illustration.




c.

Install the flow shutting valve (water valve) with the bolt.

Torque:
19 N*m (194 kgf*cm, 14 ft.*lbf)


d.

Connect the flow shutting valve (water valve) connector.