84330
1.INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY
Resistance Check
| *a | Component without harness connected
(Hazard Warning Signal Switch Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 6 (TB) - 3 (E) | Hazard warning switch off | 10 kΩ or higher |
| Hazard warning switch on | Below 1 Ω |
If the result is not as specified, replace the hazard warning signal switch assembly.
Illumination Inspection
| *a | Component without harness connected
(Hazard Warning Signal Switch Assembly) |
Apply auxiliary battery voltage to the hazard warning signal switch assembly and check that the switch illuminates.
| Measurement Condition | Condition | Specified Condition |
|---|---|---|
| Auxiliary battery positive (+) → Terminal 7 (ILL+)
Auxiliary battery negative (-) → Terminal 2 (ILL-) |
Always | Switch illumination illuminates |
If the result is not as specified, replace the hazard warning signal switch assembly.