RM38N0EC _58 Vehicle Interior _111841 HEATING / AIR CONDITIONING _0499803 FRONT EVAPORATOR TEMPERATURE SENSOR G

HEATING / AIR CONDITIONING  FRONT EVAPORATOR TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 88625 1.INSPECT NO. 1 COOLER THERMISTOR

a.

Measure the resistance according to the value(s) in the table below.

E402278C05
0.563,1.667 0.333,1.5 false 5.396,1.479 5.833,1.156 false 1.708,0.354 2.021,0.51 0.313,0.156 10 false *a 0.167,1.396 0.479,1.552 0.313,0.156 10 false *b 4.083,1.229 4.396,1.385 0.313,0.156 10 false *c 5.542,2.594 5.854,2.75 0.313,0.156 10 false *d 4.427,2.375 5.042,2.573 0.615,0.198 10 false (14) 4.969,2.385 5.583,2.583 0.615,0.198 10 false (32) 5.51,2.385 6.125,2.583 0.615,0.198 10 false (50) 6.052,2.396 6.667,2.594 0.615,0.198 10 false (68) 6.563,2.396 6.917,2.625 0.354,0.229 10 false (86) 5.865,1.063 6.177,1.219 0.313,0.156 10 false *e
*a Component without harness connected
(No. 1 Cooler Thermistor)
*b Sensing Portion
*c Resistance (kΩ) *d Temperature (°C (°F))
*e Allowable Range - -


Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 -10°C (14°F) 7.30 to 9.10 kΩ
-5°C (23°F) 5.65 to 6.95 kΩ
0°C (32°F) 4.40 to 5.35 kΩ
5°C (41°F) 3.40 to 4.15 kΩ
10°C (50°F) 2.70 to 3.25 kΩ
15°C (59°F) 2.14 to 2.58 kΩ
20°C (68°F) 1.71 to 2.05 kΩ
25°C (77°F) 1.38 to 1.64 kΩ
30°C (86°F) 1.11 to 1.32 kΩ


NOTICE:
·

Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).


If the resistance is not as specified, replace the No. 1 cooler thermistor.