84794A
1.INSPECT DEICER RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Auxiliary battery voltage not applied between terminals | 10 kΩ or higher |
If the result is not as specified, replace the deicer relay.
86220B
2.INSPECT NO. 2 INVERTER RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Auxiliary battery voltage not applied between terminals | 10 kΩ or higher |
If the result is not as specified, replace the No. 2 inverter relay.