RM36D0EC _58 Vehicle Interior _083104 HEATING / AIR CONDITIONING _0402828 AIR CONDITIONING SYSTEM(for Gasoline Model) J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model)  Front Window Fogging  


DESCRIPTION

If the front glass frequently fogs up when the air conditioning system is operated, the following causes are possible.

Malfunction Status Factor
Front glass frequently fogs
·

Compressor with pulley assembly malfunction

·

Lack of refrigerant gas

·

Cooler expansion valve (opened too far)

·

Mode damper servo malfunction

·

Mode damper and link operation (jamming)



PROCEDURE

1.CHECK REFRIGERANT SHORTAGE
a.

Prepare the vehicle according to the table below.

Measurement Condition:
Item Condition
Vehicle Condition Engine running
A/C Switch On
Ambient Temperature*1 0 to 49°C (32 to 120°F)
Air Conditioning Air Inlet Temperature*2 25 to 35°C (77 to 95°F)
Set Temperature MAX COLD
Recirculation/fresh Control Switch Recirculation
Air Vent Damper Position FACE
Blower Speed HI

NOTICE:

When the GTS is operated without the check conditions satisfied, "Refrigerant incorrect" is displayed. Select "Yes" to return to the previous screen.


HINT:
·

Refer to the GTS operator's manual for further details.

·

A message indicating a refrigerant shortage is displayed on the GTS and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.

·

DTCs are not stored when performing the refrigerant shortage check using the GTS.

·

*1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.

·

*2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.




b.

According to the GTS display, perform refrigerant gas volume check.

Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Gas Volume Check
50005 450 4578
Result:
Result Amount of Refrigerant
Refrigerant shortage Insufficient or leakage
Refrigerant correct Correct


OK:

"Refrigerant correct" is displayed on GTS.



Result:
Proceed to
OK
NG



OK

2.CHECK OPERATION

NG

2.CHECK OPERATION
a.

Press the front defroster switch on the air conditioning control assembly and check that the air outlet mode changes to DEF mode.

OK:

The air outlet mode changes to DEF mode.



Result:
Proceed to
OK
NG



OK

NG