If warm air is not discharged (airflow volume control is normal), the following malfunctions are possible.
| Malfunction Status | Factor |
|---|---|
·
No heating at all (airflow volume control is normal) ·
Air outlet temperature does not increase (airflow volume control is normal) |
·
Low engine coolant temperature ·
Air mix damper and link operation (jamming) ·
Warm-up control ·
Heater core closed waterway |
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F), Max.: 140°C (284°F) | 75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature.
|
| Tester Display |
|---|
| Coolant Temperature |
The value of the display does not change frequently.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Front Left Air Mix Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly operation | 128 to 384 | Operates between 165 to 257 pulses
(for Automatic Air Conditioning System) |
| Front Right Air Mix Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly operation | 128 to 384 | Operates between 255 to 347 pulses
(for Automatic Air Conditioning System) |
| Front Air Mix Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly operation | 128 to 384 | Operates between 165 to 257 pulses
(for Manual Air Conditioning System) |
| Tester Display |
|---|
| Front Left Air Mix Damper Control Servo Motor |
| Tester Display |
|---|
| Front Right Air Mix Damper Control Servo Motor |
| Tester Display |
|---|
| Front Air Mix Damper Control Servo Motor |
Each damper servo motor operates.
| Proceed to |
|---|
| OK |
| NG |
OK
NG