LOAD OPERATION OUTPUT
Load is turned on or off according to the operation signals and switch signals from each ECU.
| Components | Power Distribution Box Assembly |
|---|---|
| Rear Window Defogger / Mirror Heater | ○ |
| Taillight | ○ |
| Back-up Light | ○ |
| Rear Fog Light | ○ |
| Outer Rear View Mirror Assembly | ○ |
| Panel Illumination | ○ |
| Front Fog Light | ○ |
| IGR Relay | ○ |
SEMICONDUCTOR FUSE FUNCTION
When a malfunction current occurs during load operation, the current is shut off before the electrical lines emit smoke, and then load is turned off. After the current is shut off, the off condition is maintained until the operation signals or switch signals turn off.