RM36D0EC _52 Drivetrain _083071 AXLE AND DIFFERENTIAL _0403011 FRONT AXLE HUB G

AXLE AND DIFFERENTIAL  FRONT AXLE HUB  ON-VEHICLE INSPECTION  


CAUTION / NOTICE / HINT

HINT:
·

Use the same procedure for the RH and LH sides.

·

The following procedure is for the LH side.



PROCEDURE

Hide 1. PRECAUTION (for HV Model)

NOTICE:

After the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY


Hide 7.INSPECT FRONT AXLE HUB BEARING LOOSENESS

a.
C397648

Using a dial indicator with magnetic base, check for looseness near the center of the front axle hub sub-assembly.

Maximum looseness:

0.05 mm (0.00197 in.)


NOTICE:
·

Ensure that the dial indicator is set perpendicular to the measurement surface.

·

Keep the magnet of the dial indicator away from the front axle hub sub-assembly and front speed sensor.



HINT:

If the looseness exceeds the maximum, replace the front axle hub sub-assembly.



Hide 8.INSPECT FRONT AXLE HUB RUNOUT

a.
C397649

Using a dial indicator with magnetic base, check for runout on the surface of the front axle hub sub-assembly outside the front axle hub bolts.

Maximum runout:

0.05 mm (0.00197 in.)


NOTICE:
·

Ensure that the dial indicator is set perpendicular to the measurement surface.

·

Make sure to set the tip of the dial indicator towards the outside of the front axle hub bolts.

·

Keep the magnet of the dial indicator away from the front axle hub sub-assembly and front speed sensor.



HINT:

If the runout exceeds the maximum, replace the front axle hub sub-assembly.



Hide 13.CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL (for HV Model)

Hide 14. INITIALIZATION AFTER RECONNECTING AUXILIARY BATTERY TERMINAL (for HV Model)

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART