81240
1.INSPECT NO. 1 ROOM LIGHT ASSEMBLY
Check the room light.
| *a | Component without harness connected
(No. 1 Room Light Assembly) |
Apply auxiliary battery voltage to the No. 1 room light assembly and check that the room light comes on.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (B) - Auxiliary battery positive (+)
3 (E) - Auxiliary battery negative (-) |
No. 1 room light switch on | Illuminates |
If the result is not as specified, replace the No. 1 room light assembly.
Check the room light(for Door-linked).
Apply auxiliary battery voltage to the No. 1 room light assembly and check that the room light comes on.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (B) - Auxiliary battery positive (+)
1 (CTY) - Auxiliary battery negative (-) |
Always | Illuminates |
If the result is not as specified, replace the No. 1 room light assembly.