RM36D0EC _V1 General _083045 SPECIFICATIONS _0403707 DOOR LOCK F

SPECIFICATIONS  DOOR LOCK  SERVICE DATA  


UN-LOCK WARNING SWITCH ASSEMBLY:
Resistance 1 (UN+) - 2 (UN-) Switch not pushed (Key removed) 10 kΩ or higher
Switch pushed (Key inserted) Below 1 Ω


FRONT DOOR LOCK WITH MOTOR ASSEMBLY LH (for SFTM Made):
Resistance 7 (E) - 8 (LSSR) Locked 10 kΩ or higher
Unlocked Below 1 Ω
9 (L) - 7 (E) Lock Below 1 Ω
Neutral 10 kΩ or higher
10 (UL) - 7 (E) Unlock Below 1 Ω
Neutral 10 kΩ or higher


FRONT DOOR LOCK WITH MOTOR ASSEMBLY LH (for GTMC Made):
Resistance 10 (E) - 8 (LSSR) Locked 10 kΩ or higher
Unlocked Below 1 Ω
7 (L) - 10 (E) Lock Below 1 Ω
Neutral 10 kΩ or higher
6 (UL) - 10 (E) Unlock Below 1 Ω
Neutral 10 kΩ or higher


FRONT DOOR LOCK WITH MOTOR ASSEMBLY RH (for SFTM Made):
Resistance 7 (LSSR) - 8 (E) Locked 10 kΩ or higher
Unlocked Below 1 Ω


FRONT DOOR LOCK WITH MOTOR ASSEMBLY RH (for GTMC Made):
Resistance 7 (LSSR) - 5 (E) Locked 10 kΩ or higher
Unlocked Below 1 Ω


REAR DOOR LOCK WITH MOTOR ASSEMBLY LH:
Resistance 6 (LSSR) - 9 (E) Locked 10 kΩ or higher
Unlocked Below 1 Ω


REAR DOOR LOCK WITH MOTOR ASSEMBLY RH:
Resistance 6 (LSSR) - 9 (E) Locked 10 kΩ or higher
Unlocked Below 1 Ω


BACK DOOR LOCK WITH COURTESY LIGHT SWITCH ASSEMBLY (w/o Power Back Door):
Resistance 2 (ACT-) - 3 (D+) Close 10 kΩ or higher
Open Below 1 Ω


BACK DOOR LOCK WITH COURTESY LIGHT SWITCH ASSEMBLY (w/ Power Back Door):
Resistance 1 (E) - 3 (CLS) Open position Below 1 Ω
Open position → Half-latch position Below 1 Ω → 10 kΩ or higher
Half-latch position 10 kΩ or higher
Full-latch position 10 kΩ or higher
Overstroke position 10 kΩ or higher
4 (CTY) - 1 (E) Open position Below 1 Ω
Half-latch position Below 1 Ω
Half-latch position → Full-latch position Below 1 Ω → 10 kΩ or higher
Full-latch position 10 kΩ or higher
Overstroke position 10 kΩ or higher
2 (FSW) - 1 (E) Open position 10 kΩ or higher
Open position → Half-latch position 10 kΩ or higher → Below 1 Ω → 10 kΩ or higher
Half-latch position 10 kΩ or higher
Half-latch position → Full-latch position 10 kΩ or higher → Below 1 Ω → 10 kΩ or higher
Full-latch position 10 kΩ or higher
Overstroke position 10 kΩ or higher
6 (OPN) - 1 (E) Sector gear in neutral position (Sector switch on) Below 1 Ω
Sector gear not in neutral position (Sector switch off) 10 kΩ or higher