RM36D0EC _51 Engine / Hybrid System _083058 M20D-FKS ENGINE CONTROL _0401834 SFI SYSTEM C

M20D-FKS ENGINE CONTROL  SFI SYSTEM  P00FE00  EVAP System Tank Vapor Line Restricted/Blocked  


DTC SUMMARY

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P00FE00 EVAP System Tank Vapor Line Restricted/Blocked Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure is measured. When the fuel level in the fuel tank is 70% or less and the leak detection pump is operating, the EVAP system pressure decreases quickly.
·

Fuel tank vent hose

·

Fuel tank assembly (cut-off valve, roll over valve)

·

Canister

·

NO. 2 charcoal canister filter

·

ECM


Comes on DTC stored SAE: P00FE

DTC No. Monitoring Item Detection Timing Detection Logic SAE
P00FE00 EVAP vent line blocked EVAP monitoring
(ignition switch off)
2 trip P00FE

MONITOR DESCRIPTION

5 hours* after the ignition switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:

*: If the engine coolant temperature is not less than 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not less than 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.


Sequence Operation Description Duration
- ECM activation Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned off. -
A Atmospheric pressure measurement Vent valve is turned off (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system is not between 70 to 110 kPa(abs) [10.15 to 15.95 psi(abs)], ECM cancels EVAP system monitor.
60 seconds
B First reference pressure measurement In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. 360 seconds
C EVAP system pressure measurement Vent valve is turned on (closed) to shut EVAP system.
Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured.
Write down measured value as it will be used in leak check. If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*
D Purge VSV monitor Purge VSV is opened and then EVAP system pressure is measured by ECM.
Large increase indicates normal.
10 seconds
E Second reference pressure measurement After second reference pressure measurement, leak check is performed by comparing first and second reference pressure measurements.
If stabilized system pressure is higher than second reference pressure, ECM determines that EVAP system is leaking.
60 seconds
- Final check Atmospheric pressure is measured and then monitoring result is recorded by ECM. -

*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

A373424C01
1.229,0.573 1.333,0.167 1.333,0.167 1.5,0.167 true 1.625,0.719 1.667,0.344 1.667,0.344 1.833,0.344 true 2.458,0.74 2.656,0.5 2.656,0.5 2.823,0.5 true 1.75,1.49 2.167,1.073 2.167,1.073 2.5,1.073 true 2.417,1.583 2.615,1.344 2.615,1.344 2.781,1.344 true 2.875,1.969 3.083,1.833 3.083,1.833 3.25,1.833 true 0.74,1.875 0.906,1.875 0.906,1.875 1.156,1.625 true 0.667,2.25 0.833,2.25 0.833,2.25 1.521,1.854 true 1.927,2.354 1.76,2.354 1.76,2.354 1.625,2.104 true 1.229,2.938 1.417,2.667 1.417,2.667 1.583,2.667 true 1.896,3.885 2.167,3.51 2.167,3.51 2.5,3.51 true 5.25,0.573 5.354,0.167 5.354,0.167 5.521,0.167 true 5.792,1.49 6.208,1.073 6.208,1.073 6.542,1.073 true 5.948,2.365 5.781,2.365 5.781,2.365 5.646,2.115 true 5.208,2.948 5.396,2.677 5.396,2.677 5.563,2.677 true 5.844,3.885 6.115,3.51 6.115,3.51 6.448,3.51 true 0.833,4.333 1.573,4.438 true 4.802,4.333 5.542,4.438 true 0.365,0.135 0.677,0.333 0.313,0.198 10 false *a 1.521,0.083 1.833,0.281 0.313,0.198 10 false *1 1.854,0.26 2.167,0.458 0.313,0.198 10 false *9 2.854,0.417 3.167,0.615 0.313,0.198 10 false *10 2.521,1 2.833,1.198 0.313,0.198 10 false *3 2.802,1.271 3.115,1.469 0.313,0.198 10 false *11 3.271,1.74 3.583,1.938 0.313,0.198 10 false *12 0.594,1.802 0.906,2 0.313,0.198 10 false *7 0.521,2.177 0.833,2.375 0.313,0.198 10 false *8 1.938,2.271 2.25,2.469 0.313,0.198 10 false *5 1.594,2.583 1.906,2.781 0.313,0.198 10 false *1 2.521,3.427 2.833,3.625 0.313,0.198 10 false *4 0.677,4.25 1.042,4.427 0.365,0.177 10 false *6 0.365,2.552 0.677,2.75 0.313,0.198 10 false *c 4.375,0.135 4.688,0.333 0.313,0.198 10 false *b 4.385,2.552 4.698,2.75 0.313,0.198 10 false *d 3.604,3.281 3.917,3.479 0.313,0.198 10 false *e 3.615,3.677 3.927,3.875 0.313,0.198 10 false *f 5.542,0.083 5.854,0.281 0.313,0.198 10 false *1 6.563,0.99 6.875,1.188 0.313,0.198 10 false *3 5.958,2.281 6.271,2.479 0.313,0.198 10 false *6 5.583,2.594 5.896,2.792 0.313,0.198 10 false *2 6.469,3.438 6.781,3.635 0.313,0.198 10 false *4 4.646,4.25 5.01,4.427 0.365,0.177 10 false *6
*1 Purge VSV: Off (Closed) *2 Purge VSV: On (Open)
*3 Vent Valve: Off (Vent) *4 Vent Valve: On (Closed)
*5 Leak Detection Pump: Off *6 Leak Detection Pump: On
*7 Reference Orifice (0.02 inch) *8 Canister Pressure Sensor
*9 Canister *10 Fuel Tank
*11 Canister Pump Module *12 Canister Filter
*a Operation A:
Atmospheric Pressure Measurement
*b Operation B, E:
Reference Pressure Measurement
*c Operation C:
EVAP System Pressure Measurement
*d Operation D:
Purge VSV Monitor
*e Atmospheric Pressure *f Negative Pressure


(a) P00FE00: EVAP vent line blocked

During operation C, if the EVAP system pressure is below the threshold after 25 seconds, the ECM will determine that there is blockage between the fuel tank and canister, illuminate the MIL and store this DTC (2 trip detection logic).

A421323E70
0.406,0.573 1.177,0.885 0.771,0.313 10 false Purge VSV 0.438,1.115 1.208,1.427 0.771,0.313 10 false Vent Valve 0.167,1.479 1.104,1.833 0.938,0.354 10 false Leak Detection Pump 0.135,2.031 1.177,2.365 1.042,0.333 10 false EVAP Pressure 0.219,2.292 1.26,2.625 1.042,0.333 10 false Positive 0.229,2.667 1.271,3 1.042,0.333 10 false Negative 0.063,3.083 1.063,3.51 1,0.427 10 false First Reference Pressure 0.396,4.208 1.479,4.448 1.083,0.24 10 false Sequence 0.146,4.479 1.323,4.698 1.177,0.219 10 false Time (Seconds) 3.938,1 4.708,1.313 0.771,0.313 10 false ON 5.094,0.479 5.865,0.792 0.771,0.313 10 false ON 3.948,1.49 4.719,1.802 0.771,0.313 10 false ON 5.458,0.365 6.229,0.677 0.771,0.313 10 false ON: Open 6.25,0.688 7.125,1 0.875,0.313 10 false OFF: Closed 5.469,0.885 6.24,1.198 0.771,0.313 10 false ON: Closed 6.26,1.188 7.031,1.5 0.771,0.313 10 false OFF: Vent 3.469,4.385 4.792,4.677 1.323,0.292 10 false Within 15 minutes 3.906,4.125 5.229,4.417 1.323,0.292 10 false C 3.833,3.229 4.604,3.542 0.771,0.313 10 false OK 3.365,2.698 4.688,3.156 1.323,0.458 10 false 25 Seconds 1.198,3.698 2.74,4.021 1.542,0.323 10 true EVAP Vent Line Blocked 1.667,4.135 2.99,4.427 1.323,0.292 10 false A 2.583,4.125 3.906,4.417 1.323,0.292 10 false B 5.135,4.135 6.458,4.427 1.323,0.292 10 false D 5.708,4.146 7.031,4.438 1.323,0.292 10 false E 1.635,4.448 2.271,4.635 0.635,0.188 10 false 60 2.51,4.458 3.146,4.646 0.635,0.188 10 false 360 5.115,4.438 5.75,4.625 0.635,0.188 10 false 10 5.708,4.458 6.344,4.646 0.635,0.188 10 false 60 0.063,0.063 3.021,0.385 2.958,0.323 10 false EVAP Pressure when EVAP vent line blocked:


MONITOR STRATEGY

Required Sensors/Components (Main) Purge VSV
Canister pump module
Required Sensors/Components (Related) Fuel level sensor
Frequency of Operation Once per driving cycle

CONFIRMATION DRIVING PATTERN

NOTICE:
·

The Evaporative System Check (Automatic Mode) consists of 6 steps performed automatically by the GTS. It takes a maximum of approximately 24 minutes.

·

Do not perform the Evaporative System Check when the fuel tank is higher than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.

·

Do not run the engine during this operation.

·

When the temperature of the fuel is 35°C (95°F) or higher, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature less than 35°C (95°F).



HINT:
·

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>M20D-FKS (ENGINE CONTROL)>SFI SYSTEM>DTC CHECK / CLEAR



1.

Connect the GTS to the DLC3.

2.

Turn the ignition switch to ON.

3.

Turn the GTS on.

4.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

5.

Turn the ignition switch off and wait for at least 30 seconds.

6.

Turn the ignition switch to ON [A].

7.

Turn the GTS on.

8.

Enter the following menus: Powertrain / Engine / Utility / Evaporative System Check / Automatic Mode [B].

9.

After the Evaporative System Check is completed, check for All Readiness by entering the following menus: Powertrain / Engine / Utility / All Readiness.

10.

Input the DTC: P00FE00.

11.

Check the DTC judgment result.

GTS Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

Perform driving pattern after confirming DTC enabling conditions



HINT:
·

If the judgment result is NORMAL, the system is normal.

·

If the judgment result is ABNORMAL, the system is malfunctioning.

·

[A] to [B]: Normal judgment procedure.

The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.

·

When clearing the permanent DTCs, do not disconnect the cable from the battery terminal or attempt to clear the DTCs during this procedure, as doing so will clear the universal trip and normal judgment histories.