RM36D0EC _57 Power Source / Network _083089 M20D-FKS BATTERY / CHARGING _0402337 CHARGING SYSTEM U

M20D-FKS BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECM  


CHECK ECM


A525435E01
1.833,0.792 2.281,1.042 0.448,0.25 5.448,0.813 5.896,1.063 0.448,0.25 1.938,0.833 2.396,1.031 0.458,0.198 10 false C71 5.51,0.865 5.969,1.063 0.458,0.198 10 false A116

HINT:

The standard normal voltage and resistance between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
A116-22 (E1) - Body ground W-B - Body ground Ground Always Below 1 Ω
A116-31 (BATT) - A116-22 (E1) G - W-B Battery (for measuring battery voltage and for ECM memory) Always 11 to 14 V
C71-90 (LIN) - Body ground B - Body ground LIN communication line Ignition switch off
(while LIN communication stopped)
10 kΩ or higher